G3J-T
Ordering Information
■ List of Models
Number of
elements
Insulation method
Rated supply
voltage
Input method
Applicable motor
Model
3
Phototriac
12 to 24 VDC
No-voltage input
(open and short-
circuit input)
2.2 kW (5.5 A)
380 to 400 VAC
200 to 220 VAC
G3J-T405BL
0.75 kW (2.4 A)
3.7 kW (17.4 A)
2.2 kW (11.1 A)
0.75 kW (4.8 A)
G3J-T403BL
G3J-T217BL
G3J-T211BL
G3J-T205BL
Note: When ordering, specify the rated supply voltage.
Specifications
■ Ratings (at an Ambient Temperature of 25°C)
Power Supply
Rated supply voltage
Operating voltage range
Current consumption
12 to 24 VDC
10.2 to 26.4 VDC
50 mA max. (at 12 to 24 VDC)
Operation Circuit
Input current
10 mA max. (at 12 to 24 VDC)
Input method
Short-circuiting or opening terminals 1 and COM or 2 (+) and 1
No-voltage input (short-circuiting and
opening inputs) (See note.)
SSR input turned ON:A maximum residual voltage of 2 V between short-circuited terminals
SSR input turned OFF:A maximum leakage current of 0.15 mA
Relay input: For minute signals
Note: Refer to Safety Precautions for the G3J-T, G3J-S, and G3J.
Main Circuit
Item
Rated load voltage
G3J-T405BL
G3J-T403BL
G3J-T217BL
G3J-T211BL
G3J-T205BL
200 to 400 VAC (50/60 Hz)
180 to 440 VAC (50/60 Hz)
200 to 240 VAC (50/60 Hz)
180 to 264 VAC (50/60 Hz)
Load voltage range
Rated carry current (See note 1.)
5.5 A
(Ta = 40°C)
2.4 A
(Ta = 40°C)
17.4 A
(Ta = 40°C)
11.1 A
(Ta = 40°C)
4.8 A
(Ta = 40°C)
Min. load current
0.5 A
Peak-value current resistivity
220 A, 60 Hz,
1 cycle
96 A, 60 Hz,
1 cycle
500 A, 60 Hz,
1 cycle
350 A, 60 Hz,
1 cycle
150 A, 60 Hz,
1 cycle
Overload resistance
Refer to Information Common to the G3J, G3J-T, and G3J-S.
Closed current
(effective value)
AC3
AC4
AC3
AC4
55 A
66 A
44 A
55 A
24 A
174 A
111 A
48 A
28.8 A
19.2 A
24 A
208.8 A
139.2 A
174 A
133.2 A
88.8 A
111 A
57.6 A
38.4 A
48 A
Breaking cur-
rent
(effective value)
Applicable load 3-phase inductive 380 to 400 VAC, 380 to 400 VAC, 200 to 220 VAC, 200 to 220 VAC, 200 to 220 VAC,
motor (AC3 AC4
AC53-a)
2.2 kW, 5.5 A
0.75 kW, 2.4 A
3.7 kW, 17.4 A
2.2 kW, 11.1 A
0.75 kW, 4.8 A
Motors passing the AC3-class, AC4-class, and AC53-a-class switching frequency test
(Ta = 40°C) under conditions specified by OMRON. Refer to Information Common to the G3J,
G3J-T, and G3J-S.
Resistive load
200 to 400 VAC, 200 to 400 VAC, 200 to 240 VAC, 200 to 240 VAC, 200 to 240 VAC,
(AC1) (See note 2.) 5.5 A
2.4 A
17.4 A
11.1 A
4.8 A
Note: 1. The rated carry current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering
Data in the Information Common to the G3J-T, G3J-S, and G3J for details.
2. No single-phase load can be connected.
2