5秒后页面跳转
FN282-10-06 PDF预览

FN282-10-06

更新时间: 2024-01-15 05:27:31
品牌 Logo 应用领域
夏弗纳 - Schaffner 连接器电源连接器
页数 文件大小 规格书
5页 535K
描述
Compact filtered power entry module

FN282-10-06 技术参数

是否无铅: 不含铅是否Rohs认证: 符合
生命周期:Active包装说明:ROHS COMPLIANT
Reach Compliance Code:compliant风险等级:2.3
其他特性:STANDARDS: CSA, UL连接器类型:MAINS POWER CONNECTOR
联系完成配合:NOT SPECIFIED触点性别:MALE
触点材料:NOT SPECIFIED耦合类型:SNAP
DIN 符合性:NOIEC 符合性:YES
MIL 符合性:NO电源连接器额定值:10A, 250VAC
安装类型:PANEL选件:GENERAL PURPOSE
端接类型:SOLDER触点总数:3
Base Number Matches:1

FN282-10-06 数据手册

 浏览型号FN282-10-06的Datasheet PDF文件第2页浏览型号FN282-10-06的Datasheet PDF文件第3页浏览型号FN282-10-06的Datasheet PDF文件第4页浏览型号FN282-10-06的Datasheet PDF文件第5页 
IEC Inlet Filters FN 280  
DATASHEET  
Compact filtered power entry module  
Complies with IEC/EN 60601-1  
Rated currents up to 10 A  
Single or dual-fuse holder  
Fuses Ø5 x 20 mm  
Approvals  
2-pole rocker switch  
General purpose application  
Optional earth line choke (E type)  
Optional medical versions (B type)  
(CQC except HI-types)  
The FN 280 power entry module combines an IEC  
inlet, a mains filter with single or dual- fuse holder and  
a 2-pole rocker switch in a small form factor.  
Choosing FN 280 product line brings you the rapid  
availability of a standard filter associated with the  
necessary safety acceptances. Standard IEC  
connector filters are a practical solution helping you  
to pass EMI system approval in a short time. A wide  
selection on amperage ratings, fuse options,  
mounting possibilities and filters for medical  
applications are designed to offer you the desired  
solution.  
Performance indicators  
Features and benefits  
High conducted attenuation performance, based  
on chokes with high saturation resistance and  
excellent thermal behavior  
Technical specifications  
Rear/front or snap-in mounting  
Single or dual-fuse holder  
250 V, 50/60 Hz  
DC to 400 Hz  
Maximum continuous operating voltage  
Operating frequency  
2-pole rocker switch  
Custom-specific versions are available on request  
1 to 10 A @ 40°C max.  
Rated currents  
P –> PE 2000 VAC for 2 sec (standard types)  
P –> PE 2500 VAC for 2 sec (B types)  
P –> N 760 VAC for 2 sec  
High potential test voltage  
Typical applications  
Portable electrical and electronic equipment  
Consumer goods  
IP 40 according to IEC 60529  
-25°C to +85°C (25/85/21)  
Protection category  
Temperature range (operation and storage)  
Design corresponding to  
Flammability corresponding to  
MTBF @ 40°C/230 V (Mil-HB-217F)  
Fuse holder  
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939  
UL 94 V-2 or better  
EDP and office equipment  
Single-phase power supplies, switch-mode power  
supplies  
1,500,000 hours  
1 or 2 fuses (Ø5 x 20 mm) (certified to IEC 60127-6)  
Test and measurement equipment  
Medical equipment  
Power acceptance @ amb. temperature  
Marking  
max. 250 V ~ (text is print. below fuse symbol)  
Rocker switch description  
Function  
Typical electrical schematic  
2-pole, dark not illuminated  
Marking I - 0  
Inrush current 82 A  
Electrical specifications  
6,000 on-off operations according to UL 1054, TV5  
10,000 on-off operations according to ENEC  
Switch ratings  
10 A, 125 VAC; 10 A, 250 VAC; 1/3 HP  
10 A (4 A), 250 VAC*  
USA (UL) and Canada (C-UL)  
Europe (ENEC)  
50,000 cycles  
Mechanical life  
* Value in () relates to the inductive current charge: cosφ = 0.65  

与FN282-10-06相关器件

型号 品牌 描述 获取价格 数据表
FN282-1-06 Schaffner Compact filtered power entry module

获取价格

FN282-2-06 Schaffner Compact filtered power entry module

获取价格

FN282-4-06 Schaffner Compact filtered power entry module

获取价格

FN282-6-06 Schaffner Compact filtered power entry module

获取价格

FN282B-10-06 Schaffner Compact filtered power entry module

获取价格

FN282B-1-06 Schaffner Compact filtered power entry module

获取价格