Table 4. ELECTRICAL CHARACTERISTICS, ALL MODES Recommended operating conditions, unless otherwise noted, circuit
per Figure 1, minimum and maximum values are at V = 2.7 V to 5.5 V, T = −40°C to +85°C, V
= V
* 2.5 = 0.4 V to 3.6 V, V
≥
IN
A
OUT
CON
IN
V
+ 0.3 V. Typical values are given V = 3.8 V and V
= 2.5 A at T = 25°C. L = 1.5 mH, Murata DFE201610C, C = 10 mF 0402
OUT
IN
OUT A IN
Samsung CL05A106MP5NUNC, C
= 1 x 4.7 mF 0402 Murata GRM155R60J475ME47D, 2 x 10 mF 0402 Murata GRM188B30J106ME47D.
OUT
Symbol
Parameter
Condition
Min
Typ
Max
Unit
DC−DC
V
Maximum Output Voltage
DC−DC EFFICIENCY
Power Efficiency, Low−Power Auto Mode
V
= 1.44 V, V = 3.9 V
3.55
3.60
3.65
V
OUT_MAX
CON
IN
η
Power
V
OUT
V
OUT
V
OUT
= 3.1 V, I
= 1.8 V, I
= 0.5 V, I
= 250 mA
= 250 mA
= 10 mA
95
90
65
%
LOAD
LOAD
LOAD
OUTPUT REGULATION
V
V
OUT
V
OUT
V
OUT
Line Regulation
Load Regulation
Ripple
3.1 ≤ V ≤ 3.8, 100 mA
5
25
11
4
mV
mV
mV
OUT_RLine
OUT_RLoad
IN
V
20 mA ≤ I
≤ 800 mA
OUT
V
PFM Mode, I < 100 mA
OUT
OUT_Ripple
PWM Mode
TIMING
t
Startup Time
V
= 3.8 V, V from 0 V to 2.5 V,
OUT
OUT
12
18
12
ms
ms
ms
SS
IN
C
= 1 x 4.7 mF, 10 V, X5R;
2 x 10 mF, 6.3 V, X5R
t
V
V
Step Response Rise Time
Step Response Fall Time
From V to 95% V
, DV
LOAD
≤
DC−DC_TR
CON
CON
OUT
OUT
2.7 V (0.7 V – 3.4 V), R
= 5 W,
C
= 24.7 mF
OUT
t
From V
to 5% V
, DV
OUT
LOAD
DC−DC_TF
CON
CON
OUT
2.7 V (3.4 V – 0.7 V), R
= 200 W,
C
= 24.7 mF
OUT
t
Maximum Allowed Time for Consecutive
Current Limit (Note 9)
V
OUT
< 1 V
1500
4800
ms
ms
DC−DC_CL
t
Consecutive Current Limit Recovery Time
(Note 9)
DCDC_CLR
6. Dropout depends on LDO and DC−DC PFET R
and inductor DCR.
DSON
7. The current limit is the peak (maximum) current.
8. Guaranteed by design. Maximum values are based on simulation results with 50% COUT derating; not tested in production. Voltage tran-
sient only. Assumes C
= 24.7 mF (1x4.7 mF for regulator and 2x10 mF for PA decoupling capacitors).
OUT
9. Protects part under short−circuit conditions
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.
www.onsemi.com
6