Connector Terminal Box (Muting Terminals)
F39-TC5
Significantly reduces amount of wiring
between Safety Light Curtains and
Muting Sensors.
CSM_F39-TC5_DS_E_4_1
As of August 2008
• Provides IP67 protection against water and dust.
• Connection using connectors significantly reduces wiring work.
• The wiring status can be checked at a glance with the LED
indicators.
• The Support Software can be connected, enabling on-site
adjustment of a Light Curtain.
Be sure to read the “Safety Precautions” on page 7 and
the “Precautions for All Safety Sensors” .
Ordering Information
Connector Terminal Box
Classification
Applicable models
Specification
Type
Model
Model with Muting Sensor Output Mode
Model with Override Mode
F39-TC5P01
F39-TC5P02
F39-TC5N01
F39-TC5N02
F3SJ-A@@@@P@@
PNP
F3SJ-B@@@@P@@
Muting Terminals
Model with Muting Sensor Output Mode
Model with Override Mode
F3SJ-A@@@@N@@
F3SJ-B@@@@N@@
NPN
Optional Accessories (Sold separately)
Classification
Appearance
Model
Short-circuit Connector
F39-CN8
Waterproof Covers
XS2Z-22
Note: One short-circuit connector is included with the F39-T@01 for Muting Sensors.
Three waterproof covers are included with a Connector Terminal Box with Muting Sensor Output Mode (F39-TC5@01) and four waterproof
covers with a Connector Terminal Box with Override Mode (F39-TC5@02).
Order the above accessories only as spare parts.
Specifications (Refer to Instruction Sheet for details.)
Ratings
Rated voltage
Rated current
24 VDC 20% (at ambient temperature of 20°C)
Power line: 2.4 A, Signal line: 0.3 A
Characteristics
Contact resistance
40 mΩ max. (connector section)
Insulation resistance
After applying 500 VDC for 60 s: 100 MΩ min.
Speed: 10 Hz to 500 Hz to 10 Hz in 20 minutes.
Simple vibration with full amplitude of 1.52 mm or 98 m/s2 (whichever has the smaller amplitude) for two
hours each in three directions X, Y, and Z (total of 6 hours).
Measured while connector is connected.
Vibration resistance
490 m/s2 for 11 ms three times each along three axes, six directions X, Y, and Z (total of 18 times).
Measured while connector is connected. (MIL-STD-202F Test 213B, Condition A)
Shock resistance
Ambient operating temperature
Ambient operating humidity
Degree of protection
−25 to 70°C (with no icing or condensation)
25% to 85% (with no icing or condensation)
IP67
Accessories
Short-circuit connector (models with Muting Sensor outputs only), waterproof cover
1