Preliminary Technical Data
EVAL-ADM1023
TABLE 2. AD M1023 D E VICE AD D RE SSE S
C O NNE C T O R S , S WIT C H E S AND IND IC AT O R S
T he function of the various connectors, links and
indicators on the evaluation board are explained below.
Address P ins
AD D 1 (LK2)
D evice Address
Binary H ex
AD D 0 (LK3)
0(LK3 Closed)
NC(LK Open)
0(LK2 Closed)
0(LK C losed)
0011000(0)
0
T E S T C O NNE C T O R
0011001(0)
0101001(0)
0101010(0)
32
52
54
T est Connector J1 allows an external diode to be
connected between the D+ and D- terminals of the
AD M 1023
NC(LK2 Open) 0(LK3 Closed)
NC(LK2 Open) NC(LK3 Open)
C E NT R O NIC S INT E R F AC E C AB LE
T he evaluation board and the personal computer may be
connected via the printer parallel port using the contronics
cable provided. T he connections to J2 are as follows.
ST AND BY INP UT LK4
T he ADM1023 has an active low standby input, pin 15
controlled by LK4 on the evaluation board. T his is a logic
input that enables selection between normal operation
(high) and standby operation (low). Without the shorting
link the pin is high (normal mode). With the shorting link
the pin is low (standby mode). T his input performs the
same function as bit 7 of the status register
RE MO T E SE NSO R SE LE C T LK1
T he function of this jumper is to allow the user to choose
between measuring tempertature using the on-board
remote sensor and an external one connected between the
D+ and D- terminals of J1. When the middle pin is linked
to B the on-board sensor is used and when the middle pin
is linked to A the off-board sensor is used.
TABLE 1. AD M1023 SE NSO R SE LE CTIO N
LK1 P osition
Sensor Selected
External Sensor
A
B
On-baord NPN Sensor
SE RIAL BUS AD D RE SS SE LE C T
LK2 and LK3 are used to set the two LSB’s of the
ADM1023’s serial bus address, ADD0 and ADD1. T hese
pins are tri-state and can be grounded, left unconnected or
tied to VDD . T his means a total of nine addresses are
possible. However for simplicity on the evaluation board a
jumper is used to allow each pin two states ( 4 Addresses).
T he pin is floating when the shorting link is not on the
board. T he pin is grounded when the shorting link is
placed on the board. It should be noted that ADD0 and
ADD1 are only read at power up. If LK2 or LK3 are
changed while the ADM1023 is on, the change of address
will not be effective until the device has been powered off
and then on again.
As the serial bus address is seven bits, when storing it as
an 8-bit word it must be left or right justified, with either
the MSB or the LSB of the 8-bit word as zero. T he
ADM1023 evaluation software stores the 7-bit serial bus
address as left justified and makes the LSB zero. T able 2
shows the four possible addresses possible on the
evaluation board
–4–
REV. A