Anti-Surge Thick Film Chip Resistors
■ Construction
■ Dimensions in mm (not to scale)
L
a
Protective coating
Electrode (Inner%
W
Alumina substrate
t
b
Electrode
(Between%
Dimensions (mm%
a
Type
(inch size%
Mass (Weight%
[g/1000pcs.]
L
W
b
t
ERJP03
(0603)
ERJPA3
(0603)
ERJP06
(0805)
ERJP6W
(0805)
ERJP08
(1206)
ERJP14
(1210)
0.15
0.15
0.20
0.20
+0.15
+0.15
–0.10
0.15
0.10
0.20
0.20
0.20
0.20
0.10
0.10
0.10
0.10
0.10
0.10
1.60
0.80
0.80
1.25
1.25
0.15
0.15
0.25
0.35
0.30
0.45
2
2
–0.05
+0.15
–0.05
+0.15
–0.10
1.60
2.00
2.00
0.25
0.40
0.35
0.50
0.50
0.45
0.60
0.65
0.60
0.60
0.10
0.20
0.20
0.20
0.20
0.20
4
6
Electrode (Outer%
Thick film
resistive element
3.20+–00..2005 1.60+–00..0155 0.40
10
16
0.20
0.20
3.20
2.50
0.35
■ Ratings
Limiting
Maximum
Overload
Voltage(2%
(V%
Power Rating
at 70 °C
(W%
Resistance Resistance
Category
Temperature
Range (°C%
Type
(inch size%
Element
Voltage(1%
(V%
T.C.R.
Tolerance
(ꢀ%
Range
(×10–6/°C%
(Ω%
10 to 1 M
(E24, E96%
10 to 1 M
(E24, E96%
1 to 1 M
(E24%
10 to 1 M
(E24, E96%
1 to 1.5 M
(E24%
10 to 1 M R < 33 Ω
(E24, E96% 33 Ω
0.5
150
200
ERJP03
(0603)
0.2
150
200
1
5
–55 to +155
R < 10 Ω –150 to +400
:
10 Ω
R
200
<
:
0.5, 1
5
100
200
ERJPA3
(0603)
0.25
0.25
150
400
200
600
–55 to +155
–55 to +155
300
100
:
:
0.5, 1
R
<
ERJP06
(0805)
R < 10 Ω –100 to +600
:
1 to 3.3 M
(E24%
5
10 Ω R < 33 Ω
300
<
<
:
33 Ω
R
200
:
10 to 1 M
(E24, E96%
1 to 1 M
(E24%
10 to 1 M
(E24, E96%
1 to 10 M
(E24%
10 to 1 M
(E24, E96%
1 to 1 M
(E24%
1
200
ERJP6W
(0805)
0.5
0.33
0.5
150
500
200
200
1000
400
–55 to +155
–55 to +155
–55 to +155
R < 10 Ω –100 to +600
:
5
0.5, 1
5
10 Ω
R
200
<
:
100
ERJP08
(1206)
R < 10 Ω –100 to +600
:
10 Ω
R
200
<
:
0.5, 1
5
100
ERJP14
(1210)
R < 10 Ω –100 to +600
:
10 Ω
R
200
<
:
√
(1) Rated Continuous Working Voltage (RCWV) shall be determined from RCWV= Power Rating × Resistance Values, or Limiting Element Voltage
listed above, whichever less.
(2) Overload (Short-time Overload) Test Voltage (SOTV) shall be determined from SOTV=2.5 × Power Rating or max. Overload Voltage listed above
whichever less.
–55 °C
100
70 °C
Power Derating Curve
125 °C
For resistors operated in ambient temperatures above
70 °C, power rating shall be derated in accordance
with the figure on the right.
80
60
40
20
0
When the temperature of ERJP06/08/14 is 155 °C or
✽
less, the derating start temperature can be changed to
125 °C. (See the dotted line%
155 °C
–60 –40 –20
0
20 40 60 80 100 120 140 160 180
Ambient Temperature (°C%
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
04 Apr. 2013
20