品牌 Logo 应用领域
力特 - LITTELFUSE 电阻器
页数 文件大小 规格书
2页 419K
描述
5-kV防风雨感应电阻 配合SE-325、SE-330、SE-330AU使用,用于持续监测不超过5 kVac系统中的中性点接地电阻器的连续性。 配备在室外安装使用的防风雨端子。

ER-5WP 数据手册

 浏览型号ER-5WP的Datasheet PDF文件第2页 
Protection Relays  
Neutral-Grounding-Resistor Monitoring  
SE-330, SE-330HV SERIES  
Neutral-Grounding-Resistor Monitor  
Description  
The SE-330 is an advanced ground-fault and neutral-grounding-  
resistor monitoring relay that is compliant with Rule10-302 of the  
2018 Canadian Electrical Code Part I (CE Code). It measures neutral  
current, neutral-to-ground voltage, and neutral-to-ground resistance.  
It provides continuous monitoring of the neutral-to-ground path to  
verify that the neutral-grounding resistor (NGR) is intact and that it  
has not been bypassed or shorted. An open NGR renders current-  
sensing ground-fault protection inoperative and could result in a false  
belief that the system is functioning properly. A shorted NGR results  
in higher-than-expected ground-fault current.The SE-330 can be used  
with low- and medium-voltage transformers and generators with  
low- or high-resistance grounding used in processing, manufacturing,  
chemical, pulp and paper, petroleum, and water-treatment facilities.  
For high-voltage applications, use the SE-330HV. For applications that  
require conformance to Australian standards, use the SE-330AU.  
Simplified Circuit Diagram  
Resistor Monitoring  
The SE-330 combines the measured values of resistance, current,  
and voltage to continuously determine that an NGR is intact. It is  
able to detect an open or shorted resistor with or without a ground  
fault present. Sensing resistors are matched to the system voltage  
and are used to monitor NGRs on systems up to 72 kV.  
ꢄꢅ  
B
ER SERIES  
Ground-Fault Monitoring  
SE-330 SERIES  
ꢀꢁensinꢂ Resistorꢃ  
The SE-330 uses an application-appropriate current transformer to  
reliably detect ground-fault currents as small as 100 mA. Discrete-  
FourierTransform (DFT) filtering ensures that false trips due to  
harmonic noise from adjustable-speed drives do not occur. Should  
the resistor open and a ground fault subsequently occur, the SE-330  
will detect the fault through voltage measurement, while other  
current-only sensing relays would be ineffective.  
ꢀꢄꢅR ꢆonitorꢃ  
ꢀꢁR  
ꢂꢆ  
ꢂꢃ  
A
For detailed wiring diagram, see adjacent page.  
Ordering Information  
POWER  
SUPPLY  
K4 UNIT HEALTHY  
ORDERING  
NUMBER  
COMM  
CONTACT  
Pulsing Ground-Fault Location  
X
The SE-330 is capable of controlling a pulsing contactor, which is  
used to switch the NGR resistance in a pulsing-compatible NGR  
package.The resulting ground-fault current is distinguishable from  
charging currents and noise and will only appear upstream of the  
ground fault, making fault location fast and easy, even without  
isolating feeders or interrupting loads.  
SE-330  
-
X
X
-
0
0=USB Only  
1=DeviceNet  
3=EtherNet  
(Dual RJ45)  
SE-330  
for applications  
35 kV or less  
4=EtherNet  
(SC Fiber & RJ45)  
0=120/240  
Vac/Vdc  
0=Normally Open  
1=Normally Closed  
5=EtherNet  
(Dual SC Fiber)  
6=IEC61850  
(Dual RJ45)  
Accessories  
SE-330HV  
for 72 kV  
applications  
2=48 Vdc  
ER Series Sensing Resistor  
A
Required interface between the power system and the  
SE-330/SE-330HV. Eliminates hazardous voltage levels at  
the relay.  
7=IEC61850  
(SC Fiber & RJ45)  
8=IEC61850  
(Dual SC Fiber)  
B
ELCT5 Series Ground-Fault CurrentTransformer  
Sensitive ground-fault current detection (5 A primary).  
NOTE: For Australian applications, see the SE-330AU.  
ACCESSORIES  
ER Series Sensing Resistor  
Current Transformer  
SE-IP65CVR-G  
SE-MRE-600  
RK-332  
NGRM-ENC  
PGA-0520  
SE-330-SMA  
REQUIREMENT  
Required  
Required  
Optional  
Optional  
Optional  
Optional  
Optional  
Optional  
ELCT30 Series Ground-Fault CurrentTransformer  
Sensitive ground-fault current detection (30 A primary).  
Other CurrentTransformer  
For low-resistance NGRs choose a CT primary  
approximately equal to the NGR rating. Inputs are  
provided for 1- and 5- A- secondary CTs.  
SE-IP65CVR-G HingedTransparent Cover  
Watertight cover, tamper resistant, IP65 protection.  
Littelfuse reserves the right to make product changes, without notice. Material in this document is as accurate as known at the time of publication. Visit Littelfuse.com for the most up-to-date information.  
Rev: 4-D-042519  
Based on SE-330 Manual Rev: 11-A-063018  
Based on SE-330 HV Manual Rev: 5-M-101817  
© 2019 Littelfuse Protection Relays & Controls  
©
Littelfuse.com/se-330 Littelfuse.com/se-330hv  

与ER-5WP相关器件

型号 品牌 获取价格 描述 数据表
ER-600VC LITTELFUSE

获取价格

用于高达1 kV的系统。
ER60-104 VISHAY

获取价格

DC Filter Capacitors
ER60-105 VISHAY

获取价格

DC Filter Capacitors
ER60-106 VISHAY

获取价格

DC Filter Capacitors
ER60-126 VISHAY

获取价格

DC Filter Capacitors
ER60-126W VISHAY

获取价格

Film Capacitor, Polyester And Polypropylene, 6000V, 10% +Tol, 10% -Tol, 12uF, Through Hole
ER60-205 VISHAY

获取价格

DC Filter Capacitors
ER60-205W VISHAY

获取价格

Film Capacitor, Polyester And Polypropylene, 6000V, 10% +Tol, 10% -Tol, 2uF, Through Hole
ER60-206 VISHAY

获取价格

DC Filter Capacitors
ER60-206W VISHAY

获取价格

Film Capacitor, Polyester And Polypropylene, 6000V, 10% +Tol, 10% -Tol, 20uF, Through Hole