5秒后页面跳转
EHA.SH.306.XLL PDF预览

EHA.SH.306.XLL

更新时间: 2024-01-02 14:37:24
品牌 Logo 应用领域
其他 - ETC 连接器
页数 文件大小 规格书
204页 33977K
描述
CONN CIRC RCPT 6POS SOLDER CUP

EHA.SH.306.XLL 技术参数

是否Rohs认证: 符合生命周期:Active
Reach Compliance Code:unknown风险等级:5.66
连接器类型:CIRCULAR CONNECTOR联系完成配合:NOT SPECIFIED
触点材料:NOT SPECIFIEDBase Number Matches:1

EHA.SH.306.XLL 数据手册

 浏览型号EHA.SH.306.XLL的Datasheet PDF文件第4页浏览型号EHA.SH.306.XLL的Datasheet PDF文件第5页浏览型号EHA.SH.306.XLL的Datasheet PDF文件第6页浏览型号EHA.SH.306.XLL的Datasheet PDF文件第8页浏览型号EHA.SH.306.XLL的Datasheet PDF文件第9页浏览型号EHA.SH.306.XLL的Datasheet PDF文件第10页 
®
®
Definition of Ingress Protection (IP code)  
IEC 60529 outlines an international classification system  
for the sealing effectiveness of enclosures of electrical  
equipment against the intrusion into the equipment of for-  
eign bodies (i.e. tools, dust, fingers) and moisture. This  
classification system utilizes the letters «IP» (Ingress Pro-  
tection) followed by two digits.  
Example: IP 50 = IP  
5
0
IP letter code  
1st digit  
2nd digit  
Degrees of protection - First digit  
Degrees of protection - Second digit  
The first digit of the IP code indicates the degree to which  
persons are protected against contact with moving parts  
and the degree that equipment is protected against solid  
foreign bodies intruding into an enclosure.  
The second digit indicates the degree of protection of the  
equipment inside the enclosure against the harmful entry  
of various forms of moisture (e.g. dripping, spraying, sub-  
mersion, etc.)  
First digit description  
No special protection  
Second digit description  
No special protection  
Code  
Code  
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
Protection from a large part of the body such as hand  
or from solid objects greater than 50 mm in diameter  
Protection from vertically dripping water  
Protection against objects not greater than 80 mm in length  
and 12 mm in diameter  
Protection from dripping water when tilted up to 15°  
Protection from sprayed water  
Protection from entry by tools, wires, etc.,  
with a diameter or thickness greater than 2.5 mm  
Protection from entry by solid objects  
Protection from splashed water  
with a diameter or thickness greater than 1.0 mm  
Protection from the amount of dust that would interfere  
with the operation of the equipment  
Protection from water projected from a nozzle  
Protection against heavy seas, or powerful jets of water  
Protection against temporary immersion  
Dust-tight  
Protection against complete continuous submersion in water  
Selection of connectors for watertight or vacuumtight devices  
LEMO B and S series are rated IP50 only when mated. LEMO E, K and T series are rated IP66 (and over) only when  
mated. If a device must be watertight or vacuumtight when the connectors are unmated, it is important to select a water-  
tight or vacuumtight socket. You can consider the following two situations:  
A) Figure 1 shows a typical outdoor device. To ensure this  
device retains IP66 or above when connectors are  
unmated, it is important to choose a watertight socket  
from B, S, E, K or T series.  
B) Figure 2 shows a device which is subjected to pressure  
difference such as a near vacuum or pressurized gas  
and must exhibit no leakage. To ensure the device  
maintains its sealing, the socket is additionally tested for  
helium leakage (according MIL 1344A).  
Fig. 1  
Fig. 2  
your device  
your device  
epoxy  
resin seal  
FGG plug B series  
FGG plug K series  
HGG socket B series  
EGG socket K series  
Check temperature range (see section on pages 30, 47, 55, 91 and 101).  
www.lemo.com  
5

与EHA.SH.306.XLL相关器件

型号 品牌 描述 获取价格 数据表
EHA0-2400-6 ETC Voltage-Feedback Operational Amplifier

获取价格

EHA0-2500-6 ETC Voltage-Feedback Operational Amplifier

获取价格

EHA0-2502-6 ETC Voltage-Feedback Operational Amplifier

获取价格

EHA0-2505-6 ETC Voltage-Feedback Operational Amplifier

获取价格

EHA0-2510-6 ELANTEC Operational Amplifier, 1 Func, 8000uV Offset-Max, BIPolar, DIE

获取价格

EHA0-2512-6 ETC Voltage-Feedback Operational Amplifier

获取价格