DC/DC Converter
E_S-2WR2 & F_S-2WR2 series
Efficiency Vs Output Load(Vin=5V)
Efficiency Vs Input Voltage (Full Load)
100
95
90
85
80
75
70
65
60
55
50
100
90
80
70
60
50
40
30
20
10
0
F0505S-2WR2
F0505S-2WR2
4.6 4.7 4.8 4.9 5.0 5.1 5.2 5.3 5.4 5.5
Input Voltage (V)
10 20 30 40 50 60 70 80 90 100
Output Current Percentage (%)
Efficiency Vs Output Load (Vin=12V)
Efficiency Vs Input Voltage (Full Load)
100
90
80
70
60
50
40
30
20
10
0
100
95
F1212S-2WR2
90
85
80
75
70
65
60
55
50
F1212S-2WR2
11.0 11.3 11.5 11.8 12.0 12.2 12.5 12.7 13.0 13.2
Input Voltage (V)
10 20 30 40 50 60 70 80 90 100
Output Current Percentage (%)
Design Reference
1. Typical application
If it is required to further reduce input and output ripple, a filter capacitor can be connected to the input and output terminals, see Fig.3.
Moreover, choosing suitable filter capacitor is very important , start-up problems may be caused by too large capacitance. To ensured the
modules running well, the recommended capacitive load values as shown in Table 1.
Dual
Recommended capacitive load value table (Table 1)
+Vo
Vin
Cout
Cout#
0V
Vin
Cin
(μF)
Single Vout Cout
Dual Vout
(VDC)
Cin
DC
DC
DC
DC
Cout
Cout
GND
(VDC)
(VDC)
(μF)
10
2.2
1
(μF)
-Vo
Single
Vin
5
4.7
2.2
1
3.3/5
±3.3/±5
±9/±12
4.7
1
+Vo
12/15
24
9/12
Cin
15/18/24
±15/±24
0.47
GND
0V
Note: #The capacitive loads of positive and negative outputs are the same..
Fig.3
2. EMC typical recommended circuit (CLASS B)
Input voltage (VDC)
C1/C2
5/12/15
--
24
LDM
Vin
Vin
+Vo
4.7μF/50V
CY
1nF/3KV
DC/DC
LOAD
EMI
C3
C1
C2
C3
Refer to the Cout in Fig.3
-Vo
(0V)
GND
GND
LDM
6.8μH
Note: 1. 24V input series, is subject to CY (CY : 1nF/3KV).
2. It is not needed to add the component in the peripheral circuit when
parameter with the symbol of "--".
CY
Fig. 4
3. Output load requirements
To ensure the module work efficiently and reliably, during the operation, the min. output load should be no less than 10% of the full load. If the
actual output power is low, please connect a resister to the output terminal in parallel, with a recommenced resistance which is 10% of the
rated power, and derating is required during operation.
4. For more information please find the application notes on www.mornsun-power.com
2015.04.17-A/2
Page 4 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation