Power Derating Curve
100
80
Natural
convection
100LFM
200LFM
400LFM
60
40
20
0
~
-25
0
20
40
60
80
100 110
Ambient Temperature
Notes
1
2
3
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Ripple & Noise measurement bandwidth is 0-20MHz.
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not
damage these modules; however they may not meet all specifications listed.
All DC/DC converters should be externally fused at the front end for protection.
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
Specifications subject to change without notice.
4
5
6
Mechancial Drawings
Mechanical Dimensions
Pin Connections
Pin
1
Single Output
Dual Output
-Vin
-Vin
NC
7
NC
8
NC
Common
+Vout
-Vout
9
+Vout
-Vout
+Vin
0.50 [0.02]
10
16
+Vin
23.8 [0.94]
3.0
15.24 [0.60]
2.54
[0.12]
[0.10]
NC: No Connection
1
7
8
9
Bottom View
16
10
►All dimensions in mm (inches)
►Tolerance: X.X±0.25 (X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
►Pin diameter 0.5 ±0.05 (0.02±0.002)
Physical Outline
Case Size
Case Material
Weight
:
:
:
23.8x13.4x8.6mm (0.94x0.53x0.34 Inches)
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
5.1g
DS_DK02S/D_11052013
E-mail: DCDC@delta.com.tw
http://www.delta.com.tw/dcdc
P3