DDU66F
APPLICATION NOTES
Delay Devices if your application requires device
testing at a specific input condition.
HIGH FREQUENCY RESPONSE
The DDU66F tolerances are guaranteed for input
pulse widths and periods greater than those
specified in the test conditions. Although the
device will function properly for pulse widths as
small as 40% of the total delay and periods as
small as 80% of the total delay (for a symmetric
input), the delays may deviate from their values at
low frequency. However, for a given input
POWER SUPPLY BYPASSING
The DDU66F relies on a stable power supply to
produce repeatable delays within the stated
tolerances. A 0.1uf capacitor from VCC to GND,
located as close as possible to the VCC pin, is
recommended. A wide VCC trace and a clean
ground plane should be used.
condition, the deviation will be repeatable from
pulse to pulse. Contact technical support at Data
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER
DC Supply Voltage
Input Pin Voltage
Storage Temperature
Lead Temperature
SYMBOL
VCC
VIN
TSTRG
TLEAD
MIN
-0.3
-0.3
-55
MAX
7.0
VCC+0.3
150
UNITS NOTES
V
V
C
300
C
10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
(0C to 70C, 4.75V to 5.25V)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
High Level Output Voltage
VOH
2.5
3.4
V
VCC = MIN, IOH = MAX
VIH = MIN, VIL = MAX
VCC = MIN, IOL = MAX
VIH = MIN, VIL = MAX
Low Level Output Voltage
VOL
0.35
0.5
V
High Level Output Current
Low Level Output Current
High Level Input Voltage
Low Level Input Voltage
Input Clamp Voltage
Input Current at Maximum
Input Voltage
High Level Input Current
Low Level Input Current
Short-circuit Output Current
Output High Fan-out
IOH
IOL
VIH
VIL
VIK
IIHH
-1.0
20.0
mA
mA
V
V
V
2.0
-60
0.8
-1.2
0.1
VCC = MIN, II = IIK
VCC = MAX, VI = 7.0V
mA
IIH
IIL
IOS
20
-0.6
-150
25
VCC = MAX, VI = 2.7V
VCC = MAX, VI = 0.5V
VCC = MAX
mA
mA
mA
Unit
Load
Output Low Fan-out
12.5
Doc #97020
2/5/97
DATA DELAY DEVICES, INC.
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
2