Reference Only
Spec No. JENF243F-0031C-01
P4/10
Item
Specification
Products shall not be damaged.
Test Method
No.
7.5 Withstanding
Voltage
Test Voltage : 2.5 times for Rated Voltage
Time : 1 to 5 seconds
Charge Current : 10 mA max.
It shall be applied between input / output terminal
and ground terminal.
7.6 Temperature
Characteristics
Meet item 3.
Capacitance shall be measured at each step specified
in Table 3 after reaching the thermal equilibrium.
The capacitance change against the capacitance at
step 3 shall be calculated.
Table3
Step
Temp.
(°C)
1
2
3
4
5
+20±2 -40±2 +20±2 +85±2 +20±2
7.7 Solderability
Along the circumference of terminal
Flux : Ethanol solution of rosin,25(wt)%
shall be covered with new solder at least (dipped for 5 to 10 seconds)
Pre-heat : 150±10℃, 60~90 s
75%.
Solder : Sn-3.0Ag-0.5Cu
Solder Temperature 245±5℃
Immersion Time : 2 ± 0.5 seconds
Immersion Depth :
2 to 2.5 mm from the bottom of the body.
7.8 Resistance to
Meet Table 4.
Flux : Ethanol solution of rosin,25(wt)%
(dipped for 5 to 10 seconds)
Soldering Heat① Table 4
Pre-heat : 150±10℃, 60~90 s
Solder : Sn-3.0Ag-0.5Cu
Appearance
No damaged.
within ± 30%
No damaged.
Capacitance
Change
Solder Temperature : 270 ± 5 °C
Immersion Time : 3± 0.5 seconds
Immersion Depth :
1.6 ± 0.7 mm from the bottom of the body.
Then measured after exposure in the room
condition for 4 to 24hours.
Withstanding
Voltage
Resistance to
Soldering Heat②
Soldering iron output: 30W
Tip temperature : 370±10°C
Soldering time : 5s(+0/-1s)
Temperature : 60°C
Meet Table 5.
7.9 Humidity
Humidity : 90 to 95 %(RH)
Time : 500 hours(+24-0 hours)
Then measured after exposure in the room
condition for 4 to 24hours.
Table 5
Appearance
Capacitance
No damaged.
within ± 30%
Change
Temperature : 40 ± 2°C
Humidity : 90 to 95 %(RH)
Time : 500 hours(+24-0 hours)
Applying Voltage : 1H/ Rated Voltage 50VDC
2A/ Rated Voltage 100VDC
7.10 Humidity Life
Inslation
Resistance
10MΩ min.
Then measured after exposure in the room
condition for 4 to 24hours.
Temperature : 85 ± 3°C
7.11 Heat Life
Applying Voltage : 1H/ Rated Voltage 50VDC
2A/ Rated Voltage 100VDC
Time : 500 hours(+24-0 hours)
Then measured after exposure in the room
condition for 4 to 24hours.
MURATA MFG.CO., LTD