2 / 3
ON/OFF
Logic
Output Current
Efficiency(%)
12Vin, 3.3Vdc@6A
Model Name
Package
Input Voltage
Output Voltage
Min. Load
Max. Load
DOS06-12T
Negative
Positive
Negative
Positive
Negative
SMD
Vo(set)≦3.63V
Vin = 8.3-14Vdc
DOS06-12T-P
DOH06-12T
DOH06-12T-P
DOH06-12TA
Vertical Mounting
0.75 ~ 5.0Vdc
0A
6A
89%
SIP
Horizontal Mounting
SIP
Vo(set)>3.63V
Vin = 8.3-13.2Vdc
DOH06-12TA-P Positive
Note
1. BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at 40ºC.
MIL-HDBK-217F Notice2 @Ta=25 ºC, Full load(Ground, Benign, controlled environment).
2. External with C = 1μF ceramic//10μF tantalum capacitors.
out
3. External with C = 2×150μF polymer capacitors.
out
4. Output voltage programmable from 0.7525V to 5V by connecting a single resistor (shown as Rtrim in Table 1) between the TRIM and GND pins of the
module.To calculate the value of the resistor Rtrim for a particular output voltage Vo, use the following equation:
10500
- 1000
]
Rtrim =
[
Ω
Vo – 0.7525
5. It’s necessary to equip the external input capacitors at the input of the module. The capacitors should connect as close as possible to the input
terminals that ensuring module stability. The external C is 2×47μF ceramic capacitors at least.
in
6. Device code with suffix “-P” – Positive logic(On/Off is open collector/drain logic input; Signal referenced to GND )
Device code with no suffix – Negative logic (On/Off pin is open collector/drain logic input with external pull –up resistor; signal referenced to GND)
7. Case 1 :On/Off input is set to logic low (module on) and then input power is applied (delay from instant at which Vin=Vin(min.) until Vo=10% of
Vo(set))
8. Case 2 :Input power is applied for at least one second and then the On/Off input is set to logic low (delay form instant at which Von/off=0.3V until
Vo=10% of Vo(set))
DOS06-12T, Vo=3.3V, Derating Curve
7
6
5
4
3
2
1
0
Fig. 1
20
30
40
50
60
70
80
90
AMBIENT TEMPERATURE,TA(
)
℃
Table 1
Rtrim (KΩ)
Vo(set) (V)
0.7525
1.2
1.5
1.8
2.5
3.3
5
Open
22.46
13.05
9.024
5.009
3.122
1.472