Applicable standard
Operating
Storage
-35 C to +85 C(Note1)
40% to 80% (Note2)
-10 C to +60 C(Note3)
40% to 70% (Note3)
temperature range
Operating
humidity range
temperature range
Storage
humidity range
Applicable connector
Rating
Voltage
Current
250 V AC
AWG20 to 24: 3A
AWG26: 2A
DF1E-*S-2.5C
Voltage
AC 30V
AWG20 to 22: 3A
AWG24 to 28: 1A
AWG30: 0.5A
UL,CSA
AWG28: 1A
AWG30: 0.5A
Current
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
Electric characteristics
Contact resistance millivolt
20 mV MAX, 1 mA(DC or 1000 Hz).
30 m MAX.
X
-
level method.
Insulation resistance
500 V DC.
1000 M MIN.
X
X
-
-
Voltage proof
650 V AC for 1 min.
No flashover or breakdown.
Mechanical characteristics
Mechanical operation
30times insertions and extractions.
① Contact resistance: 30 m MAX.
② No damage, crack or looseness of parts.
X
X
X
-
-
-
Vibration
Shock
Frequency 10 to 55 Hz, single amplitude
0.75 mm, at 2 h, for 3 directions.
490 m/s2 duration of pulse 11 ms at 3 times for 3
directions.
① No electrical discontinuity of 1 s.
② No damage, crack or looseness of parts.
Environmental characteristics
Rapid change of
temperature
Temperature -55→ 5 to 35→+85→ 5 to 35 c
Time 30→ 5 max→ 30→ 5 max min
① Contact resistance: 30 m MAX.
② Insulation resistance: 1000 M MIN.
③No damage, crack or looseness of parts.
X
X
X
-
-
-
Under 5 cycles.
Damp heat
(Steady state)
Exposed at 40 ± 2 c, 90 to 95 , 96 h.
① Contact resistance: 30 m MAX.
② Insulation resistance: 500 M MIN.
③No damage, crack or looseness of parts.
No deformation of case of excessive
looseness of the terminals.
Resistance to soldering
heat
1) Automatic soldering (flow)
Solder temperature,
260 ℃
for
Immersion,duration, 10 sec.
2) Manual soldering
Soldering iron temperature : 300 ℃,
Soldering time : 3 sec.
No strength on contact.
Solderability
Remarks
Soldered at solder temperature,
Solder shall cover a minimum of
95 of the surface being immersed.
X
235 c for insertion duration,
5
s.
-
Note1: Include the temperature rising by current.
Note2:No condensing.
Note3:Apply to the condition of long term storage for unused products before pcb on board.
After pcb board,operating temperature and humidity range is applied for interim storage during transportation.
Count
Description of revisions
Designed
Checked
Date
0
△
Approved
Checked
Designed
Drawn
KI.AKIYAMA
KI.AKIYAMA
TS.KUMAZAWA
MI.SAKIMURA
15.06.16
15.06.16
15.06.15
15.06.15
TO
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing no.
ELC-336779-35-00
Part no.
DF1EG-*P-2.5DSA(35)
CL541
Specification sheet
Hirose electric co., ltd.
0
△
1/1
Code no.
FORM HD0011-2-1