D5V0H1U2LPQ
Maximum Ratings (@TA = +25°C, unless otherwise specified.)
Characteristic
Peak Pulse Power Dissipation
Symbol
PPP
Value
350
25
Unit
W
Conditions
8/20µs, per Figure 3
Peak Pulse Current
A
8/20µs, per Figure 3
IPP
ESD Protection – Contact Discharge
ESD Protection – Air Discharge
±30
±30
kV
kV
IEC 61000-4-2 Standard
IEC 61000-4-2 Standard
VESD_CONTACT
VESD_AIR
Thermal Characteristics
Characteristic
Package Power Dissipation (Note 5)
Symbol
Value
Unit
mW
250
500
PD
Thermal Resistance, Junction to Ambient (Note 5)
Operating and Storage Temperature Range
RθJA
C/W
-65 to +150
TJ, TSTG
C
Electrical Characteristics (@TA = +25°C, unless otherwise specified.)
Characteristic
Reverse Working Voltage
Symbol
VRWM
IR
Min
—
Typ
—
Max
5.5
1.0
7.4
9.0
14.0
—
Unit
Test Conditions
V
A
V
—
Reverse Current (Note 6)
—
0.1
—
VR = 5.0V
IR = 1mA
Reverse Breakdown Voltage
6.2
—
VBR
—
IPP = 5A, tp = 8/20μs
Reverse Clamping Voltage
V
VCL
—
—
IPP = 25A, tp = 8/20μs
IPP = 16A, TLP = 10/100ns
IPP = 30A, TLP = 10/100ns
VR = 0V, f = 1MHz
—
8.6
9.8
190
Clamping Voltage (Note 7)
Capacitance
V
VCL
CT
—
—
—
—
pF
Notes:
5. Device mounted on FR-4 PCB pad layout (2oz copper) as shown on Diodes Incorporated’s suggested pad layout, which can be found on our website at
http://www.diodes.com/package-outlines.html.
6. Short duration pulse test used to minimize self-heating effect.
7. Transmission Line Pulse Test (TLP) settings: tP = 100ns, tR = 10ns, ITLP and VTLP averaging window is from 70ns to 90ns.
250
225
100
75
Note 5
200
175
150
125
100
75
50
25
0
50
25
0
0
0
25
50
75
100
125
150 175
25
50
TA, AMBIENT TEMPERATURE
Figure 2 Pulse Derating Curve
150 175 200
75 100 125
(
(癈 )
oC)
TA, AMBIENT TEMPERATURE (°C)
Figure 1 Power Derating Curve
2 of 5
www.diodes.com
August 2022
© 2022 Copyright Diodes Incorporated. All Rights Reserved.
D5V0H1U2LPQ
Document number: DS42846 Rev. 1 - 2