Universal-Instrument MINIPAN SE352
in Housing for Panel-Mount 48 x 96 mm
-
-
Resolution 0.1 °C (up to 999.9 C)
Display in °C or °F
Withits4digit,14mmhighdisplay,
Digital Panelmeters of MINIPAN
SE352-seriesallowtheaccurate
display of different values in the
range -1999 ... +9999.
Measuring inputs AC (True
RMS), DC current and voltage
and measuring of restistance
and of temperatures with various
sensors are combined in one
instrument.
Two programmable switching
points allow applications as
limit-switch or 2- or 3-point con-
troller.
With EasyLimit the switching
points can be set easily. Other
parameters are blocked and
thus protected from unindended
manipulation.
MINIPAN SE352
AC/DC-measuring inputs:
-
•
300 mV for measuring current with external
shunt
1 and 5 A for direct measuring of current (or AC
with external transformer)
500 V
10 V for standard signals
20 mA for standard signals
AC-measuring TrueRMS
-
-
-
-
-
Measuring of resistance:
-
•
•
Ranges 0...500 Ω, 0...30 kΩ
Part numbers:
D440101
Easy programming with 3 buttons and supporting
display:
-
D440110
with analog output
Display (zero, fullscale, decimal point)
2 switching points with hysteresis and delays
EasyLimit for easy setting of alarms
Switching with automatic reset or interlocked
MIN/MAX-contacts or operating-/closed cur-
rent mode of relays
Storage of MIN- and MAX-values
Average of multiple measurings
Simulation of operation
-
-
-
-
-
-
-
-
-
With its analog output (option)
it is in addition a measuring-
transducer.
The display can be easily pro-
grammed by the user (e.g. input
DC4-20mA/display0-350.0m/s
or 0...200 Ω / 0...3000 mm or AC
0-5 A / 0-400.0 A).
Code-lock against manipulation of settings
Outputs 2 potential-free change-over contacts (co)
Supply-voltage for external measuring transducer
4-20 mA
In addition the built-in universal
power-supply AC/DC 24-240 V
makes it even more versatile.
•
•
Sticker with different measuring units included
Terminals pluggable
Mounting dimensions 48 x 96 mm
Splash-proof frontside IP54
Supply-voltage AC/DC 24-240 V
Option: analog output 4...20 mA (insulated when
externally supplied)
•
•
•
•
•
•
•
Temperature:
-
Pt 100 (RTD) , Pt 1000,
KTY83 and KTY84 in 2- or
3-wire connection
-
-
Thermocouples type B, E,
J, K, L, N, R, S, T
Measuring range –170 ...
+1820 °C
2011-01-30
128 ZIEHL industrie-elektronik, 74523 Schwäbisch Hall, Germany, +49 791 504-0, info@ziehl.de, www.ziehl.de