5秒后页面跳转
D2HW-A202DR PDF预览

D2HW-A202DR

更新时间: 2023-08-15 00:00:00
品牌 Logo 应用领域
欧姆龙 - OMRON /
页数 文件大小 规格书
8页 1274K
描述
Snap Acting/Limit Switch

D2HW-A202DR 数据手册

 浏览型号D2HW-A202DR的Datasheet PDF文件第2页浏览型号D2HW-A202DR的Datasheet PDF文件第3页浏览型号D2HW-A202DR的Datasheet PDF文件第4页浏览型号D2HW-A202DR的Datasheet PDF文件第5页浏览型号D2HW-A202DR的Datasheet PDF文件第6页浏览型号D2HW-A202DR的Datasheet PDF文件第8页 
D2HW  
Sealed Ultra Subminiature Basic Switch  
Precautions  
Please refer to "General Information" for correct use.  
Cautions  
Correct Use  
Degree of Protection  
Mounting  
• Do not use this product underwater.  
• Turn OFF the power supply before mounting or removing the  
Switch, wiring, or performing maintenance or inspection.  
Failure to do so may result in electric shock or burning.  
• For M3-screw mounting models, use M3 mounting screws with  
plane washers or spring washers to securely mount the  
Switch.  
Although molded lead wire models satisfy the test conditions  
for the standard given below, this test is to check the ingress of  
water into the switch enclosure after submerging the Switch in  
water for a given time. Satisfying this test condition does not  
mean that the Switch can be used underwater.  
JIS C0920:  
D
2
H
W
Tighten the screws to a torque of 0.27 to 0.29 N·m {27.5 to  
29.5 gf}. Exceeding the specified torque may result in  
deterioration of the sealing or damage.  
Degrees of protection provided by enclosures of electrical  
apparatus (IP Code)  
IEC 60529:  
• For models with posts, secure the posts by thermal caulking or  
by pressing into an attached device. When pressed into an  
attached device, provide guides on the opposite ends of the  
posts to ensure that they do not fall out or rattle.  
Thermal caulking conditions varies according to the equipment,  
jig and base used for switch mounting. Consult your OMRON  
sales representative for details.  
Degrees of protection provided by enclosures (IP Code)  
Degree of protection: IP67  
(check water intrusion after immersion  
for 30 min. submerged 1m underwater)  
• Do not operate the Switch when it is exposed to water spray,  
or when water drops adhere to the Switch surface, or during  
sudden temperature changes, otherwise water may intrude  
into the interior of the Switch due to a suction effect.  
• Prevent the Switch from coming into contact with oil and  
chemicals.  
Operating Body  
• Use an operating body with low frictional resistance and of a  
shape that will not interfere with the sealing rubber, otherwise  
the plunger may be damaged or the sealing may deteriorate.  
Otherwise, damage to or deterioration of Switch materials may  
result.  
Handling  
• Do not use the Switch in areas where it is exposed to silicon  
adhesives, oil, or grease. Otherwise faulty contact may result  
due to the generation of silicon oxide.  
• Do not handle the Switch in a way that may cause damage to  
the sealing rubber.  
• When handling the Switch, ensure that pressure is not applied  
to the posts in the directions shown in the following diagram.  
Also, ensure that uneven pressure or pressure in a direction  
other than the operating direction is not applied to the Actuator  
as shown in the following diagram. Otherwise, the post,  
Actuator, or Switch may be damaged, or the service life may  
be reduced.  
Soldering  
When soldering the lead wire to the terminal, first insert the  
lead wire conductor through the terminal hole and then  
conduct soldering.  
Make sure that the temperature of the soldering iron tip does  
not exceed 300°C, and complete the soldering within 3  
seconds. Do not apply any external force for 1 minute after  
soldering.  
Soldering at an excessively high temperature or soldering for  
more than 3 seconds may deteriorate the characteristics of the  
Switch.  
In case of automatic soldering, please do not apply the heat  
beyond 260°C within 5 seconds. Pay careful attention so that  
flux or solder liquid does not flow over the edge of the PCB  
panel.  
Wiring Molded Lead Wire Models  
• When wiring molded lead wire models, ensure that there is no  
weight applied on the wire or that there are no sharp bends  
near the parts where the wire is drawn out.  
Otherwise, damage to the Switch or deterioration in the  
sealing may result.  
Side-actuated (Cam/Dog) Operation  
• When using a cam or dog to operate the Switch, factors such  
as the operating speed, operating frequency, push-button  
indentation, and material and shape of the cam or dog will  
affect the durability of the Switch. Confirm performance  
specifications under actual operating conditions before using  
the Switch in applications.  
Using Micro Loads  
• Even when using micro load models within the operating  
range shown below, if inrush/surge current occurs, it may  
increase the contact wear and so decrease durability.  
Therefore, insert a contact protection circuit where necessary.  
7

与D2HW-A202DR相关器件

型号 品牌 描述 获取价格 数据表
D2HW-A202DS OMRON Snap Acting/Limit Switch

获取价格

D2HW-A211D OMRON Sealed Subminiature Snap Action Switch

获取价格

D2HW-A211DL OMRON Snap Acting/Limit Switch,

获取价格

D2HW-A211DLS OMRON Snap Acting/Limit Switch

获取价格

D2HW-A211DR OMRON Snap Acting/Limit Switch

获取价格

D2HW-A211DRS OMRON Snap Acting/Limit Switch

获取价格