5秒后页面跳转
D2FS-F-N PDF预览

D2FS-F-N

更新时间: 2022-02-26 11:09:41
品牌 Logo 应用领域
欧姆龙 - OMRON /
页数 文件大小 规格书
4页 301K
描述
Ultra Subminiature Basic Switch

D2FS-F-N 数据手册

 浏览型号D2FS-F-N的Datasheet PDF文件第1页浏览型号D2FS-F-N的Datasheet PDF文件第2页浏览型号D2FS-F-N的Datasheet PDF文件第3页 
D2FS  
Ultra Subminiature Basic Switch  
Precautions  
Refer to General Information.  
Cautions  
Correct Use  
Soldering  
Handling  
When using automatic soldering baths, we recommend solder-  
ing at 260°C within 5 seconds. Make sure that the liquid sur-  
face of the solder does not flow over the edge of the board.  
When soldering terminals manually, perform soldering within 3  
seconds at iron tip temperature not higher than 350°C. Do not  
apply any external force for at least 1 minute after soldering.  
When applying solder, keep the solder away from the case of  
the Switch and do not allow solder or flux to flow into the case.  
When handling the Switch, ensure that uneven pressure or, as  
shown in the following diagram, pressure in a direction other  
than the operating direction is not applied to the Actuator, oth-  
erwise the Actuator or Switch may be damaged, or durability  
may be decreased.  
incorrect  
incorrect  
incorrect  
Side-actuated (Cam/Dog) Operation  
incorrect  
When using a cam or dog to operate the Switch, factors such  
as the operating speed, operating frequency, push-button  
indentation, and material and shape of the cam or dog will  
affect the durability of the Switch. Confirm performance speci-  
fications under actual operating conditions before using the  
Switch in applications.  
Using Micro Loads  
Even when using micro load models within the operating  
range, inrush currents or surges may decrease the life expect-  
ancy of the Switch. Therefore, insert a contact protection cir-  
cuit where necessary.  
Application Environment  
Do not use the Switch in locations that are subject to toxic gas,  
silicon, excessive dust, excessive dirt, high temperatures, high  
humidity, sudden temperature changes, water splashes, or oil  
splashes.  
Otherwise, damage resulting by faulty contact of the Switch con-  
tacts, corrosion, or other causes, or other functional faults may  
occur.  
±Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.  
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad  
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious  
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or  
equipment, and be sure to provide the system or equipment with double safety mechanisms.  
Note: Do not use this document to operate the Unit.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Contact: www.omron.com/ecb  
Cat. No. B121-E1-04  
0117(0207)(O)  
4

与D2FS-F-N相关器件

型号 品牌 描述 获取价格 数据表
D2FS-F-N-A OMRON Ultra Subminiature Basic Switch

获取价格

D2FS-F-N-A1 OMRON Ultra Subminiature Basic Switch

获取价格

D2FS-F-N-T OMRON Snap Acting/Limit Switch,

获取价格

D2F-T OMRON Snap Action Switch

获取价格

D2FW-G OMRON Watertight Snap Action Switch

获取价格

D2FW-G071M OMRON Watertight Snap Action Switch

获取价格