D2FS
Ultra Subminiature Basic Switch
Ratings
Rated voltage
Resistive load
6 VDC
0.1 A
Note: The rating values apply under the following test conditions.
Ambient temperature: 20 ± ±2°C
Ambient humidity: 65 ± ±5%
Operating frequency: 20 operations/min
Characteristics
Pin plunger models: 1 mm to 500 mm/s
Lever models: 5 mm to 500 mm/s
Operating speed
Pin plunger models: 200 operations/min max.
Lever models: 100 operations/min max.
Mechanical
Operatiing frequency
Electrical
Insulation resistance
30 operations/min max.
100 MΩ min. (at 500 VDC)
100 mΩ max.
Contact resistance (initial value)
Between terminals of same polarity
600 VAC 50/60 Hz 1 min
Between current carrying metal parts and ground
Dielectric strength
1,500 VAC 50/60 Hz 1 min
Between each terminal and non-current carrying
metal part
Vibration resistance
Shock resistance
Malfunction *1
Destruction
Malfunction *1
Mechanical
Electrical
10 to 55 Hz, 1.5 mm double amplitude
1,000 m/s2 max.
300 m/s2 max.
100,000 operations min. (at 30 ops./min.)
10,000 operations min. (at 30 ops./min.)
IP40
Durability *2
Degree of protection
Ambient operatingtamperature
Ambient operation humidity
Weight
–20 to +70°C (at 60%RH Max.) (with no icing or condensation)
85%RH max. (for +5 to +35°C)
Approx. 0.5 g (pin plunger models)
Note: The data given above are initial values.
*1. The values are at Free Position and Total Travel Position values for pin plunger, and Total Travel Position value for lever.
Close or open circuit of the contact is 1 ms max.
*2. For testing conditions, consult your OMRON sales representative.
2