5秒后页面跳转
CC2431ZRTC PDF预览

CC2431ZRTC

更新时间: 2024-01-29 23:01:07
品牌 Logo 应用领域
TAOS 电信集成电路
页数 文件大小 规格书
16页 194K
描述
System-on-Chip for 2.4 GHz ZigBee/ IEEE 802.15.4 with Location Engine

CC2431ZRTC 技术参数

是否无铅: 含铅是否Rohs认证: 符合
生命周期:Obsolete零件包装代码:QFN
包装说明:QFN-48针数:48
Reach Compliance Code:compliantHTS代码:8542.39.00.01
Factory Lead Time:1 week风险等级:7.15
Is Samacsys:NJESD-30 代码:S-XQCC-N48
JESD-609代码:e4长度:7 mm
湿度敏感等级:3功能数量:1
端子数量:48封装主体材料:UNSPECIFIED
封装代码:QCCN封装形状:SQUARE
封装形式:CHIP CARRIER峰值回流温度(摄氏度):260
认证状态:Not Qualified表面贴装:YES
电信集成电路类型:TELECOM CIRCUIT端子面层:Nickel/Palladium/Gold (Ni/Pd/Au)
端子形式:NO LEAD端子位置:QUAD
处于峰值回流温度下的最长时间:NOT SPECIFIED宽度:7 mm
Base Number Matches:1

CC2431ZRTC 数据手册

 浏览型号CC2431ZRTC的Datasheet PDF文件第4页浏览型号CC2431ZRTC的Datasheet PDF文件第5页浏览型号CC2431ZRTC的Datasheet PDF文件第6页浏览型号CC2431ZRTC的Datasheet PDF文件第8页浏览型号CC2431ZRTC的Datasheet PDF文件第9页浏览型号CC2431ZRTC的Datasheet PDF文件第10页 
CC2431  
2.1.1 Reference Coordinates  
The Location Engine requires a set of between  
three and 16 reference coordinates [x0, y0, x1,  
y1, …, x15, y15] to be input. The reference  
coordinates express each reference nodes  
position in meters, as unsigned values in the  
interval [0, 63.75] meters. The finest possible  
readout resolution is 0.25 meter. The format  
used is fixed-point data with the two LSBs  
representing the fractional part and the  
remaining six bits representing the integer  
part, thus e.g. 63.75 is represented as 0xFF.  
reference coordinates are being written. Once  
the coordinate load process commences  
(LOCENG.REFLD =1), 16 coordinate pairs  
must always be written. However, it is possible  
for the Location Engine to use less than 16  
reference coordinates, by marking certain  
reference coordinates as unused. Zeros shall  
be used to fill the unused reference coordinate  
slots, and they will be interpreted as unused  
when 0.0 is loaded as the RSSI value for  
those reference coordinates.  
Reference coordinates are loaded into the RF  
register REFCOORD. Before writing to  
REFCOORD, a 1 must be written to the register  
bit LOCENG.REFLD to indicate that a set of  
The reference coordinates are written in the  
order [x0, y0, x1, y1, …, x15, y15] to the  
register REFCOORD. After all coordinates have  
been written, a 0 is written to the register bit  
LOCENG.REFLD.  
2.1.2 Measured Parameters  
After the reference coordinates have been  
written, a set of measured parameters must be  
input to the Location Engine. These  
parameters consist of two radio parameters:  
Four search boundary coordinates and 16  
RSSI values. The radio parameters are the  
values A and n. These radio parameters are  
used in the Engine’s algorithm used to find the  
estimated location. The parameters A and n  
can be adjusted to describe the propagation  
environment in which a network of devices will  
operate.  
2.1.2.1 Parameter Definitions  
The measured parameters are described in  
this section together with how these should be  
estimated.  
2.1.2.1.1  
Parameter A  
The radio parameter A is defined as the  
absolute value of the average power in dBm  
received at a close-in reference distance of  
one meter from the transmitter, assuming an  
The Engine expects the parameter A to be in  
the range [30.0, 50.0] with precision 0.5. The  
parameter A is given as an unsigned fixed-  
point value where the LSB bit is the fractional  
bit and the remaining bits are the integer part.  
A typical value for A is 40.0.  
omni-directional radiation pattern.  
For  
example, if the mean received power at one  
meter is -40 dBm, the parameter A is specified  
as 40.  
2.1.2.1.2  
Parameter n  
The radio parameter n is defined as the path  
loss exponent that describes the rate at which  
the signal power decays with increasing  
distance from the transmitter. This decay is  
proportional to d-n where d is the distance  
between transmitter and receiver.  
As an example, in the case when the value  
n=2.98 is found from measurements, the  
closest available value of n in the lookup table  
is 3.00, corresponding to index 13. Therefore,  
the integer value 13 is used for the parameter  
n written to the Location Engine.  
The actual parameter n value written to the  
Location Engine is an integer index value  
selected from a lookup table shown in Table 2.  
Refer to section 2.1.2.1.3 in order to find the  
value for n to be used.  
CC2431 Data Sheet (Rev. 2.01) SWRS034B  
Page 7 of 15  
 

与CC2431ZRTC相关器件

型号 品牌 获取价格 描述 数据表
CC2431ZRTCR TAOS

获取价格

System-on-Chip for 2.4 GHz ZigBee/ IEEE 802.15.4 with Location Engine
CC2431ZRTCRG3 TI

获取价格

SPECIALTY TELECOM CIRCUIT, QCC48, 7 X 7 MM, GREEN, QFN-48
CC24500N POWEREX

获取价格

Super Fast Recovery Dual Diode Modules 50 Amperes/300-600 Volts
CC2450D1U ETC

获取价格

RELAY SSR DUAL 50A ZERO PNL MNT
CC2450D1UH CRYDOM

获取价格

Trigger Output SSR, 2-Channel, 4000V Isolation, ROHS COMPLIANT, PLASTIC PACKAGE-8
CC2450D1UR ETC

获取价格

RELAY SSR DUAL 50A RNDM PNL MNT
CC2450D1URH CRYDOM

获取价格

Solid State Relay
CC2450D1V ETC

获取价格

RELAY SSR DUAL 50A ZERO PNL MNT
CC2450D1VH ETC

获取价格

RELAY SSR DUAL 50A ZERO PNL MNT
CC2450D1VR CRYDOM

获取价格

Trigger Output SSR, 2-Channel, 4000V Isolation, ROHS COMPLIANT, PLASTIC PACKAGE-8