Cable with open-ended wires
CAM8.A3-11230397
Article Number: 11230397
Vue d'ensemble
■
M8, female, A-coded, 3-poles; PUR, 100 cm, shielded, free cable end
Dragchain capable
Head A: IP65, IP67
Cable: good resistance against chemicals, flames, oils
Halogen free
■
■
■
■
Caractéristiques techniques
Side A
Cable
Head A: Connection
Head A: Angle cable outlet
Head A: Gender
M8
Length tolerance
Cable length
+ 5 cm
90°
100 cm
Female
Acceleration (C-track)
AWG
max. 5 m/s²
22
Head A: Coding
A
Head A: No. of poles
Head A: LED
3
Bending radius (fixed)
Torsion speed
min. 5 × outer diameter
max. 35 cycles/min
min. 10 × outer diameter
3
No
Head A: Width across flats
Head A: Tightening torque
AF9
Bending radius (mobile)
Cable type
0,4 Nm
Head A: Knurled nut mate-
rial
Zinc-pressure die casting, surface Ni
Cable weight
approx. 44 g/m
42 × 0,1 mm
5 mm ± 5%
Copper, bare
PUR
Conductor structure
Cable diameter
Conductor: Material
External sheath: Material
Insulation: Material
Shielding: Material
Head A: Body color
Head A: Gasket material
Labeling sleeve side A
Side B
Black
FKM
Yes
PP
Head B: Connection
Labeling sleeve side B
Cables
Open-ended wires
Yes
Copper, tinned
approx. 5000000 Cycles
No. of bending cycles (C-
track)
Cable length
100 cm
+ 5 cm
20 mm
Oui
Nominal voltage
300 V
Length tolerance
Stripping length
Shielded
No. of torsion cycles
Paired stranding
approx. 2000000 Cycles
No
Single wire diameter
Cable: Test voltage
Torsion stress in °
0,1 mm
Conductor structure
AWG
42 × 0,1 mm
22
2 kV AC core-core ; 2 kV AC core-shield
± 30 °/m
External sheath: Material
External sheath: Color
Cable diameter
Wire cross section
Cable
PUR
Total stranding
3 wires strand
max. 3,3 m/s
max. 5 m
0,34 mm²
No
Black
Travel speed (C-track)
Traversing path (horizontal)
Wire cross section
Wire processing
5 mm ± 5%
0,34 mm²
Cable: Temperature range
(mobile)
- 25 ...+ 80 °C
- 40 ...+ 80 °C
30 V AC/DC
Wire diameter incl. isolation
External sheath: Color
Données électriques
Operating voltage
1,25 mm ± 5%
Black
Cable: Temperature range
(fixed)
max. 50 V AC / 60 V DC
30 V AC/DC
Operating voltage (only UL
listed)
Operating voltage (only UL
listed)
Shielded
Oui
Nominal voltage
300 V
Shielding: Covering
Bending radius (fixed)
Number of wires
approx. 80 %
25 mm
3
Contact resistance
max. 30 mOhm
max. 4 A
Operating current per
contact
Number and diameter of
wires
3x0,34
www.baumer.com
Fiche technique – CAM8.A3-11230397
Page 1 sur 3