Coupling torque
The allowable coupling torques have to be tested under full bundle
conditions of the connectors to VG95319, part 2, test no. 5.8.2.
Mechanical Features
Ambient temperature
Standard insulator material
–55°/125°C (– 67/257°F)
Shell Size
Allowable coupling torque
closing and opening Nm max.
1,7
Opening Nm min.
FKM insulator material*
–30°/200°C (– 22/392°F)
10SL
12S
14S
16S/16
18
0,15
0,23
0,35
0,46
0,58
0,7
2,5
3,6
5,5
8
Safety provisions**
In mated condition
General (all connectors):
IP67 acc. to ISO20653
20
9
22
11
14
17
19
23
0,8
VG 95234 Connectors:
1 bar for 16h
24
0,8
28
0,92
1,03
1,03
32
IP69K Version Connectors:
Plug with Universal Endbell and receptacle with o-ring
IP68 (1bar for 16h); IP69K (Jet water sealed) acc. to ISO20653
36
Contact retention
Vibration test
The contact retention has to be tested according to VG95319,
part 2, test no. 5.4. Test force direction = Mating direction.
200 m/s2 at 10 to 2000 Hz
Mating cycles
Contact size
Test force
500 min.
AWG
N
10
–
30
Withdrawal force per contact
15S/15
25
16S/16
35
55
80
90
95
The corresponding separating force has to be measured according
to VG95319, part 2, test no. 5.7. using the required test gage and
DIN EN60512-16-5.
12
8
60/100
160
4
500
0
Contact size
Metric
10
Separating force min
N
AWG
Gage
–
0,3
G 0,99
G 1,56
G 2,36
G 3,58
G 5,69
G 9,04
Materials
Shell - Aluminum alloy
Standard finishes
15S/15
25
16S/16
1,0
1,5
3,0
4,0
8,5
12
8
60/100
160
4
Cadmium (A66), VG approved,, 500h salt spray, highly conductive
ZnCo black (A239) RoHS, VG approved, 48h salt spray, highly
conductive
ZnNi blue grey (A240) RoHS, 500h salt spray, highly conductive
ZnCo black (A232) RoHS, 200h salt spray, conductive
ZnCo green (A233) RoHS, 200h salt spray, highly conductive
500
0
Gauge
(see also VG95234, Part 1)
Insulator and grommets
Polychloroprene (Standard)
FKM (High temperature)
Contacts - Copper alloy
Standard finish - Hard silver
Special finish - A176 nickel and hard gold plating
Gauge
Contact diameter d
+0,01
L
–1
7
G 0,99
G 1,56
G 2,36
G 3,58
G 5,69
G 9,04
0,99
1,56
2,36
3,58
5,69
9,04
9
* consult factory for availability
12
13
13
13
** Longitudinal sealing: The connector is not sealed against fluids entering through
the cable, as the sealing lips of the single wire sealing are pressing against the
jacket of the individual conductors.
Only solutions as PG or ME adapters as well as universal endbell provide for
longitudinal sealing provided that both ends of the cable are sealed correctly.
Dimensions shown in mm
Specifications and dimensions subject to change
www.ittcannon.com
7