Mounting Instructions
Mounting Instruction, straight cable connector
Stripping Lengths
Screw contacts
Measure a 1) Measure b
pay attention at keying
2)
2)
with internal cable clamping
18+1
7+1
7+1
without internal cable clamping 25+1
Solder contacts
with internal cable clamping
14+1
4+1
4+1
without internal cable clamping 22+1
Crimp contacts 0,14 – 0,50 mm2
3+0,5
clamping ring with mounted gasket
0,50 – 1,5 mm2
3,5+1
14+1
22+1
back shell
with internal cable clamping
without internal cable clamping
tightening torque
1,5 - 2 Nm
1) PE + 2mm 2) end splice recommended
internal
cable clamping
additionally
included gasket
male contact
TR 22 x 2
insert with
locking ring
cable nut
tightening torque
1,5 - 2 Nm 1)
tightening torque max. 0,3 Nm 1)
female contact
insert with
locking ring
Mounting Instruction, right angled cable connector
Stripping Lengths
Measure a 1) Measure b
Screw contacts
2)
without internal cable clamping 35+1
7+1
4+1
pay attention at keying
Solder contacts
without internal cable clamping 32+1
3+0,5
Crimp contacts
0,14 – 0,5 mm2
3,5+1
0,50 – 1,5 mm2
32+1
without internal cable clamping
1) PE + 2mm 2) end splice recommended
right angled back shell
tightening torque
1 - 2 Nm
clamping ring with
mounted gasket
male contact
insert with
locking ring
TR 22 x 2
shell
cable nut
tightening torque
additionally
included
gasket
female contact
insert with
locking ring
1,5 - 2 Nm 1)
1) The tightening torque figures can vary depending on the cable you use.