BU52001GUL,BU52011HFV,BU52021HFV,
BU52015GUL,BU52025G,BU52051NVX, BD7411G
Technical Note
BU52051NVX , BU52011HFV (Unless otherwise specified, VDD=1.80V, Ta=25℃)
BU52021HFV,BU52025G (Unless otherwise specified, VDD=3.0V, Ta=25℃)
LIMIT
PARAMETERS
SYMBOL
UNIT
CONDITIONS
MIN
TYP MAX
Power Supply Voltage
VDD
2.4
3.0
3.6
V
BopS
BopN
BrpS
BrpN
BhysS
BhysN
-
3.7
-3.7
2.9
-2.9
0.8
5.5
-
-
-0.8
-
-
Operate Point
Release Point
mT
-5.5
0.8
-
-
-
mT
Hysteresis
mT
ms
V
0.8
Period
Tp
-
50
-
100
-
17
※
VDD
-0.4
BrpN<B<BrpS
Output High Voltage
VOH
IOUT =-1.0mA
B<BopN, BopS<B
IOUT =+1.0mA
17
※
Output Low Voltage
VOL
-
-
-
-
-
0.4
12
-
V
Supply Current
IDD(AVG)
IDD (EN)
IDD (DIS)
8
μA
mA
μA
Average
Supply Current During Startup Time
Supply CurrentDuring Standby Time
4.7
3.8
During Startup Time Value
During Standby Time Value
-
※17 B = Magnetic flux density
1mT=10Gauss
Positive (“+”) polarity flux is defined as the magnetic flux from south pole which is direct toward to the branded face of the sensor.
After applying power supply, it takes one cycle of period (TP) to become definite output.
Radiation hardiness is not designed.
BD7411G (Unless otherwise specified, VDD=5.0V, Ta=25℃)
LIMIT
PARAMETERS
Power Supply Voltage
SYMBOL
VDD
UNIT
V
CONDITIONS
MIN
4.5
TYP MAX
5.0
5.5
BopS
BopN
BrpS
-
3.4
-3.4
3.0
5.6
Operate Point
Release Point
Hysteresis
mT
-5.6
-
1.5
-
mT
mT
BrpN
-
-
-
-3.0
0.4
0.4
-1.5
BhysS
BhysN
-
-
18
※
BrpN<B<BrpS
Output High Voltage
Output Low Voltage
Supply Current
VOH
VOL
IDD
4.6
-
-
-
0.4
4
V
V
IOUT =-1.0mA
B<BopN, BopS<B
IOUT =+1.0mA
18
※
-
-
2
mA
※18 B = Magnetic flux density
1mT=10Gauss
Positive (“+”) polarity flux is defined as the magnetic flux from south pole which is direct toward to the branded face of the sensor.
Radiation hardiness is not designed.
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
2010.01 - Rev.C
5/19