5秒后页面跳转
BU52021HFV-TR PDF预览

BU52021HFV-TR

更新时间: 2024-01-10 05:57:45
品牌 Logo 应用领域
罗姆 - ROHM /
页数 文件大小 规格书
20页 469K
描述
暂无描述

BU52021HFV-TR 数据手册

 浏览型号BU52021HFV-TR的Datasheet PDF文件第11页浏览型号BU52021HFV-TR的Datasheet PDF文件第12页浏览型号BU52021HFV-TR的Datasheet PDF文件第13页浏览型号BU52021HFV-TR的Datasheet PDF文件第15页浏览型号BU52021HFV-TR的Datasheet PDF文件第16页浏览型号BU52021HFV-TR的Datasheet PDF文件第17页 
BU52001GUL,BU52011HFV,BU52021HFV,  
BU52015GUL,BU52025G,BU52051NVX, BD7411G  
Technical Note  
Intermittent Operation at Power ON  
Power ON  
VDD  
Startup time  
Standby time  
High  
Standby time  
Startup time  
Supply current  
(Intermittent action)  
Indefinite  
OUT  
(No magnetic  
field present)  
Indefinite  
OUT  
(Magnetic  
field present)  
Low  
Fig.38  
The Omnipolar detection Hall IC adopts an intermittent operation method in detecting the magnetic field during startup, as  
shown in Fig. 38. It outputs to the appropriate terminal based on the detection result and maintains the output condition  
during the standby period. The time from power ON until the end of the initial startup period is an indefinite interval, but it  
cannot exceed the maximum period, 100ms. To accommodate the system design, the Hall IC output read should be  
programmed within 100ms of power ON, but after the time allowed for the period ambient temperature and supply voltage.  
BD7411G don’t adopts an intermittent operation method.  
Magnet Selection  
Of the two representative varieties of permanent magnet, neodymium generally offers greater magnetic power per volume  
than ferrite, thereby enabling the highest degree of miniaturization, Thus, neodymium is best suited for small equipment  
applications. Fig. 39 shows the relation between the size (volume) of a neodymium magnet and magnetic flux density. The  
graph plots the correlation between the distance (L) from three versions of a 4mm X 4mm cross-section neodymium magnet  
(1mm, 2mm, and 3mm thick) and magnetic flux density. Fig. 40 shows Hall IC detection distance – a good guide for  
determining the proper size and detection distance of the magnet. Based on the BU52011HFV, BU52015GUL operating  
point max 5.0 mT, the minimum detection distance for the 1mm, 2mm and 3mm magnets would be 7.6mm, 9.22mm, and  
10.4mm, respectively. To increase the magnet’s detection distance, either increase its thickness or sectional area.  
10  
9
t=3mm  
8
7
t=1mm  
t=2mm  
6
5
4
3
2
1
7.6mm 9.2mm  
10.4mm  
0
0
2
4
6
8
10  
12  
14  
16  
18  
20  
Distance between magnet and Hall IC [mm]  
Fig.39  
X
Magnet material: NEOMAX-44H (material)  
Maker: NEOMAX CO.,LTD.  
Magnet  
t
Y
t
X=Y=4mm  
t=1mm,2mm,3mm  
L: Variable  
Flux density measuring point  
Magnet size  
Fig.40 Magnet Dimensions and  
Flux Density Measuring Point  
www.rohm.com  
© 2010 ROHM Co., Ltd. All rights reserved.  
2010.01 - Rev.C  
14/19  

与BU52021HFV-TR相关器件

型号 品牌 描述 获取价格 数据表
BU52025G ROHM Hall effect Switch

获取价格

BU52025G-TR ROHM Hall Effect Sensor, 0.8mT Min, 5.5mT Max, 0.40-2.60V, Plastic/epoxy, Rectangular, 6 Pin, S

获取价格

BU52040HFV ROHM Bipolar latch type Hall effect IC

获取价格

BU52040HFV_10 ROHM Bipolar Latch Hall IC

获取价格

BU52040HFV-TL ROHM Magnetic Field Sensor, -5mT Min, 5mT Max, Bipolar, Plastic/epoxy, 6 Pin, Surface Mount

获取价格

BU52040HFV-TR ROHM Bipolar Latch Hall IC

获取价格