SPOC - BTS6460SF
Overview
Configuration and status diagnosis are done via SPI. The SPI is daisy chain capable. The device provides a
current sense signal per channel that is multiplexed to the diagnosis pin IS. It can be enabled and disabled via SPI
commands. An over load and over temperature flag is provided in the SPI diagnosis word. A multiplexed switch
bypass monitor provides short-circuit to VBB diagnosis. In OFF state a current source can be switched to the output
of one selected channel in order to detect an open load.
Additionally, there is an integrated PWM generator implemented, which allows autonomous PWM operation with
programmable phase shifts, duty cycles and PWM frequencies. The status diagnosis and the current sense signal
is available for each channel.
The SPOC - BTS6460SF provides a fail-safe feature via limp home input pin.
The power transistors are built by N-channel vertical power MOSFETs with charge pumps.
Protective Functions
•
•
•
•
•
•
•
•
•
Reverse battery protection with external components
ReversaveTM - Reverse battery protection by self turn on of all channels
Short circuit protection
Over load protection
Thermal shutdown with latch and dynamic temperature sensor
Over current tripping
Over voltage protection
Loss of ground protection
Electrostatic discharge protection (ESD)
Diagnostic Functions
•
•
•
•
•
•
•
•
Multiplexed proportional load current sense signal (IS)
Enable function for current sense signal configurable via SPI
High accuracy of current sense signal at wide load current range
Current sense ratio (kILIS) configurable for LEDs or bulbs for channel 2 and 3
Very fast diagnosis in LED mode
Feedback on over temperature and over load via SPI
Multiplexed switch bypass monitor provides short circuit to VBB detection
Integrated, in two steps programmable current source for open load in OFF-state detection
Application Specific Functions
Fail-safe activation via LHI pin
•
Applications
•
•
High-side power switch for 12 V grounded loads in automotive applications
Especially designed for standard exterior lighting like high beam, low beam, indicator, parking light and
equivalent LEDs
•
•
Load type configuration via SPI (bulbs or LEDs) for optimized load control
Replaces electromechanical relays, fuses and discrete circuits