BR250
Miniature
25 Amps • 1PDT
To MIL-PRF-6106
SPECIFICATIONS
GENERAL
Operate/Release Time:
DC Coil
AC Coil
15 ms max 50 ms max
Contact Arrangement .......................... 1PDT (1 Form C)
Weight..........................................................1.6 oz approx.
Designed to meet the requirements of MIL-PRF-6106
Excluding bounce time at nominal coil voltage
Contact Bounce Time....................................... 1 ms max
@ rated contact load, 28 VDC
PERFORMANCE
Contact Voltage Drop:
Before Life............................. 150 mv max @ 25 Amps
and 6 VDC
Contact Rating (Note 1):
Resistive ................................... 25 Amps @ 28 VDC or
115/208V 400 Hz
After Life................................ 175 mv max @ 25 Amps
and 6 VDC
(Case Grounded)
ENVIRONMENTAL
Temperature Range............................... -70oC to +125oC
Vibration (Note 2).............................. 0.12" DA 10 - 70 Hz
30 G's 70 - 3,000 Hz
Inductive ........................15 Amps @ 115/208V 400 Hz
(Case Grounded)
10 Amps @ 28 VDC
Shock (Operating)(Note 2) ......................... 200 G's 6 ms
(Case Grounded)
ELECTRICAL CHARACTERISTICS
Duty Cycle........................................................Continuous
Insulation Resistance............................... 100 megohms
@ 500V 25oC
Motor......................................... 10 Amps @ 28 VDC or
115/208V 400 Hz
(Case Grounded)
Dielectric Strength:
Lamp .......................................... 5 Amps @ 28 VDC or
115/208V 400 Hz
Sea Level:
Contact to Case................................... 1,250 VRMS
Contact to Coil ..................................... 1,250 VRMS
Coil to Case ......................................... 1,000 VRMS
Across Open Contacts ........................ 1,250 VRMS
80,000 Feet:
(Case Grounded)
Life .......................50,000 operations minimum @ rated
resistive load, 125oC
Pull In Power............................................500 mw approx.
All Points ................................................. 350 VRMS
MIL-PRF-6106/19 QUALIFIED
Notes:
1. For other ratings consult the factory.
3. AC coil line frequency 50 to 400 Hz.
2. For applications requiring higher shock and
vibration, consult the factory.
14930 E. Alondra Blvd., La Mirada, CA 90638-5752 (714) 994-6500 FAX (714) 994-3013
W:2000, Rev. 4