10W LED Driver
10W-BPH Series
Constant Current Mode
FEATURES:
● AC Input 90~264 Vac Nominal
● AC Inrush current: 40 A at 240 Vac Cold start
● Protection: SCP / OVP / OTP
● High Operating Ambient Temp.: -20℃ ~ +60℃
● Surge Protection: L-N 0.5 kV
● Safety: UL 1310 / PSE
● EMI: CE / Meets FCC
● Comply with Indoor/Outdoor Waterproof (IP 67)
● Warranty: 2 years (refer to LinkCom warranty policy)
● RoHS Compliant
PRODUCT SPECIFICATION
OUTPUT
OUTPUT
DC OUTPUT
POWER(W)
DC OUTPUT
VOLTAGE(V)
MODEL
CURRENT
EFFICIENCY O/P NOISE(P-P,V)
CURRENT(mA)
TOLERANCE
BPHE010C201-50
BPHE010C251-50
BPHE010C301-50
BPHE010C351-50
BPHE010C401-50
BPHE010C451-50
BPHE010C501-50
BPHE010C601-50
BPHE010C701-50
BPHE010C751-50
BPHE010C801-50
9.6
10
3-48
3-40
3-34
3-30
3-25
3-24
3-20
3-17
3-15
3-13
3-12
216-264
234-286
288-352
333-407
369-451
414-506
459-561
549-671
636-781
684-836
729-891
70%
70%
70%
70%
70%
70%
70%
70%
70%
70%
70%
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
─
─
─
─
─
─
─
─
─
─
─
10.88
10.5
10
10.8
10
10.2
10.5
9.75
9.6
ELECTRICAL SPECIFICATION
INPUT VOLTAGE RANGE
INPUT FREQUENCY
ACTIVE POWER FACTOR
THD
90-264 Vac, 127-373 Vdc, Normal: 100-240 Vac
Range: 47-63 Hz, Normal: 50-60 Hz
NA
NA
TURN ON DELAY TIME
AC CURRENT
3200ms, 2000ms at full load 115 Vac / 230 Vac
<0.3 A 110 Vac; <0.15A 230 Vac
Cold Start 40 A at 240 Vac
< 0.7 mA / 264 Vac
INRUSH CURRENT (typ)
LEAKAGE CURRENT
SHORT CIRCUIT PROTECTION
OVER VOLTAGE PROTECTION
OVER TEMP. PROTECTION
OVER CURRENT PROTECTION
OPERATING TEMP.
SCP will restart automatically after the fault condition is removed
OVP will restart automatically after the fault condition is removed
OTP will restart automatically after the fault condition is removed
NA
-20 ℃ ~ +60 ℃
STORAGE TEMP.
-40 ℃ ~ +80 ℃
RELATIVE HUMIDITY
SAFETY
10% to +90%, non-cond.
UL 1310 / PSE
EMI
EN55015 / Meets FCC Part15
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
DIMENSION (L*W*H)
I/P-O/P:4.242 kVdc I/P-CASE:4 kVdc
I/P-O/P :100M Ω / 500 Vdc / 25℃ / 70% RH
97.5 * 40 * 30.5 mm【3.84 * 1.57 * 1.2 inch】
(1) All parameters specified at 230 Vac input unless otherwise noted.
(2) All specifications typical at 25℃, unless otherwise noted, at normal line and load.
(3) Ripple and noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk at 20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
(6) 100% Production tested.
*REFERENCE: www.linkcom.com.tw
*Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw