5秒后页面跳转
BGE.3M.200.XAZ PDF预览

BGE.3M.200.XAZ

更新时间: 2022-09-29 11:52:49
品牌 Logo 应用领域
其他 - ETC /
页数 文件大小 规格书
44页 13951K
描述
CONN CAP FOR .3M. RCPT

BGE.3M.200.XAZ 数据手册

 浏览型号BGE.3M.200.XAZ的Datasheet PDF文件第1页浏览型号BGE.3M.200.XAZ的Datasheet PDF文件第2页浏览型号BGE.3M.200.XAZ的Datasheet PDF文件第3页浏览型号BGE.3M.200.XAZ的Datasheet PDF文件第5页浏览型号BGE.3M.200.XAZ的Datasheet PDF文件第6页浏览型号BGE.3M.200.XAZ的Datasheet PDF文件第7页 
®
®
Environmental performance  
Characteristics  
Value  
IEC international  
MIL-spec tests  
-55°C/+200°C 1) (HEl model: -20°C/+80°C)  
-20°C/+200°C 2) (HEl model: -20°C/+80°C)  
IP 68 (at 2 m, 15Hr)  
Operating temperature (mated)  
Ingress protection index  
Fungus  
IEC 60529  
Satisfied - by material analysis  
60 sec. front and back face  
MIL-STD 810F-508.5  
EIA-364-104A  
Flammability  
Fluid contamination 3)  
Sand and dust 4)  
Lightning strike  
Altitude-low temp 5)  
Salt fog 6)  
Fuels, gasoline, hydraulic oils, solvents, de-icing  
6 hr, 55°C, blowing < 150 µm dust  
10 K amps - 6 times  
MIL-STD-810F method 504  
MIL-STD 810F-510.4  
EIA-364-75  
-65°C; 40’000 feet and 400 VAC  
Alum. shell (up to 500Hr), Brass shell (1000Hr)  
5 cycles: -65°C to +150°C  
EIA-364-105A  
IEC 60512-6 test 11f  
IEC 60512-11-4  
EIA-364-26  
Thermal shock  
Altitude immersion  
Humidity  
EIA-364-32 test condition IV  
EIA-364-03  
No moisture on contacts  
21 days at 95%  
IEC 60068-2  
EIA-364-31 method IV  
Note:  
1) Shell material code C + Silicone O-ring (see page 1).  
2) Shell material code I/X + FPM O-ring (see page 1).  
3) Connectors immersed at both 70°C and 25°C according to specification. Connectors are then inspected, no visual signs of damage seen.  
Fuels: Kerosene, JP4, (Nato F40) at 70°C +/- 2°C. Gasoline: ASTM 4814. Hydraulic oils: Mineral oil based MIL-H-5606.  
Solvents: Isopropanol. De-icing fluids: 25% ethylene glycol.  
4) No signs of damage, connectors opened and closed without difficulty. Dust or sand was not inside connector.  
5) Wired mated connectors = no voltage breakdown, shell to all contacts (connected together) w/400 VAC after 1 hour at -65° C at 40’000 feet altitude.  
6) Corrosion resistance. Inspection: salt deposits shall be removed by gentle wash in running water with light brushing using soft brush.  
Aluminium Shell (material code: X) max: 48 hours, (material code: I) max: 500 hours. Brass shell (material code: C) over 1000 hours.  
Electrical performance  
Characteristics  
Value  
IEC international  
MIL-spec tests  
EIA-364-21  
Insulation resist. (at ambient temp.) 6)  
Dielectric withstanding volt. (sea level)  
Contact resistance  
> 1012 Ω, > 1010 Ω (after humidity)  
See table page 25, 26, 27  
IEC 60512-2 test 3a  
IEC 60512-2 test 4a  
IEC 60512-2 test 2a  
IEC 60512-3 test 5a  
IEC 60512-2-6  
EIA-364-20  
EIA-364-06  
See table below 7)  
Current rating  
See insulator configuration page 25, 26, 27  
< 1.5m Ω  
Shell to shell conductivity  
EIA-364-83  
EIA-364-66  
EIA-364-66  
Shielding effectiveness, low frequency  
Shielding effectiveness, high frequency  
80 dB up to 1GHz  
70 dB (3GHz), 58 dB (6GHz), 40 dB (10GHz)  
Note: 6) After humidity test: 21 days at 95% RH according to IEC 60068-2. Insulation resistance measured between the contacts and contact/shell.  
Contact resistance 7)  
Value  
IEC 60512-2 test 2a  
ø A  
(mm)  
0.5  
0.7  
0.9  
1.3  
mΩ  
8.7 6.1 4.8 3.6  
Notes: 7) after 5000 mating cycles and the salt spray test according to IEC 60512-6 test 11 f.  
2
www.lemo.com  

与BGE.3M.200.XAZ相关器件

型号 品牌 描述 获取价格 数据表
BGE.4M.200.XAZ ETC CONN CAP

获取价格

BGE.5M.200.XAZ ETC CONN CAP FOR .5M. RCPT

获取价格

BGE.LM.200.XAZ ETC CONN CAP FOR .LM. RCPT

获取价格

BGE67BO NXP Optical receiver module

获取价格

BGE67BO/SC NXP Optical receiver module

获取价格

BGE67BO/SC0 ETC FIBER OPTIC RECEIVER

获取价格