Surge arrester
B88069X6821B201
H38-E800XP
2-electrode arrester
Features
Applications
Suitable for direct strikes
Very fast response time
Stable performance over life
High insulation resistance
RoHS-compatible
AC power line N-PE application
Class I – surge protection
Electrical specifications
DC spark-over voltage 1) 2)
> 600
V
V
Front of wave spark-over voltage
- at 1.2/50 µs, 6 kV
< 1500
Breakdown time
- typical values
< 100
< 20
ns
ns
Insulation resistance at 100 VDC
> 1
GΩ
Class I according to IEC 61643-11
Max. continuous operating voltage at 50/60 Hz
Nominal discharge current 8/20 µs
Impulse current 10/350 µs
Uc
In
Iimp
If
255
100
100
100
V
kA
kA
A
Follow current at 50/60 Hz
AC discharge current (TOV 3) at 1200 V)
1 operation
DC discharge current
1 operation
50 Hz, 0.2 s
300
A
0.5 s
400
A
g
Weight
~ 100
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, blue positive
-40 ... +90
40/090/21
°C
800 YY O
800
YY
O
- Nominal voltage
- Year of production
- Non radioactive
1)
At delivery AQL 0.65 level II, DIN ISO 2859
In darkness without storage
TOV – Temporary over voltage
2)
3)
PPD AB PD / PPD AB PM
Version: 05 / 2018-06-19
Please read Cautions and warnings and
Page 2 of 6