Surge arrester
B88069X5641T902
ES1200XSMD
2-electrode arrester
Soldering parameter
Reflow soldering
Reflow profile
features
Sn- Pb eutectic Pb-free
assembly
assembly
Preheat and soak
- Temperature min
- Temperature max
- Time
Tsmin
Tsmax
tsmin to tsmax
100 °C
150 °C
60 ... 120 s
150 °C
200 °C
60 ... 180 s
Average ramp-up
rate
Tsmax to Tp
max. 3 °C/ s
max. 3 °C/ s
Liquidous
temperature
Time at liquidous
TL
tL
183 °C
60 ... 150 s
217 °C
60 ... 150 s
Peak package body
temperature *,
Classification
temperature **
Tp, TC
220 ... 235 °C ** 245 ... 260 °C **
Time (tp) ** within
5 °C of the specified
classification
20 s ***
30 s ***
temperature (TC)
Average ramp-down
rate
Tp to Tsmax
max. 6 °C/ s
max. 6 min
max. 6 °C/ s
max. 8 min
Time 25 °C to peak
temperature
* = Tolerance for peak profile temperature (Tp) is defined as a supplier minimum
and a user maximum.
** = For details please refer to JEDEC J-STD-020D.
*** = Tolerance for time at peak profile temperature (tp) is defined as a supplier
minimum and a user maximum.
Cautions and warnings
Do not operate surge arresters in power supply networks, whose maximum operating voltage
exceeds the minimum spark-over voltage of the surge arresters.
Electromagnetic fields and ionizing radiation may affect the electrical characteristics of the
arrester. The impact of such effects (inductive and capacitive field distortion from adjacent
components) must be avoided by appropriate circuit design measures.
Surge arresters may become hot in the event of longer periods of current stress (burn risk). In the
event of overload the connectors may fail or the component may be destroyed.
If the contacts of the surge arresters are defective, current load can cause sparks and loud
noises.
Surge arresters must be handled with care and must not be dropped.
Do not continue to use damaged surge arresters.
The shown SMD pad dimensions represent a safe way to mount the arrester and are a
recommendation of the manufacturer. During the reflow process it must be assured that no solder
material reduces the insulation distance between the pads below the arrester.
SMD surge arresters should be soldered within 24 month after shipment.
Display of ordering codes for EPCOS products
The ordering code for one and the same EPCOS product can be represented differently in data
sheets, data books, other publications, on the EPCOS website, or in order-related documents such as
shipping notes, order confirmations and product labels. The varying representations of the
ordering codes are due to different processes employed and do not affect the specifications of
the respective products. Detailed information can be found on the Internet under
www.epcos.com/orderingcodes
PPD AB PD / PPD AB PM
2015-07-10
Please read Cautions and warnings and
Page 4 of 5
Important notes at the end of this document.