Surge arrester
B88069X4760T902
M51-C90XSMD
2-electrode arrester
Features
Applications
Small size
High current rating
Modem
XDSL-splitter
Data lines
Tuner
Very fast response time
Stable performance over life
Very low capacitance
High insulation resistance
Excellent SMD handling
RoHS-compatible
Antenna
Electrical specifications
DC spark-over voltage 1) 2)
90
20
72
V
%
V
V
Tolerance
Min.
Max.
108
Impulse spark-over voltage
at 100 V/µs - for 99% of measured values
- typical values of distribution
< 450
< 350
V
V
at 1 kV/µs
- for 99% of measured values
- typical values of distribution
< 600
< 550
V
V
Service life
10 operations
1 operation
10 operations
1 operation
1 operation
50 Hz, 1 s
50 Hz, 0.18 s (9 cycles)
8/20 µs
8/20 µs
10/350 µs
5
10
5
10
1
A
A
kA
kA
kA
G
pF
Insulation resistance at 50 VDC
Capacitance at 1 MHz
> 1
< 1
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 15
~ 0.8
~ 60
V
A
V
Weight
~ 1
g
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking blue negative
°C
40 ... +90
40/090/21
90 YY O
90
YY
O
- Nominal voltage
- Year of production
- Non radioactive
Certification
UL 497B (E163070)
1)
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode
2)
Terms in accordance with ITU-T Rec. K.12, IEC 61663-2 and IEC 61643-311
PPD AB PD / PPD AB PM
2015-07-30
Please read Cautions and warnings and
Page 2 of 5
Important notes at the end of this document.