Surge arrester
B88069X3971B502
T33-A250XF1
3-electrode arrester
Features
Applications
Very small size
Fast response time
High current rating
Stable performance over life
Very low capacitance
High insulation resistance
Reliable failsafe device
RoHS-compatible
Branch exchange (MDF)
Line protection
Station protection
Electrical specifications
DC spark-over voltage 1) 2) 3)
DC spark-over voltage 1) 2) 6)
200 … 300
200 … 450
V
V
Impulse spark-over voltage 3)
at 100 V/µs - for 99% of measured values
< 500
< 400
V
V
- typical values of distribution
at 1 kV/µs
- for 99% of measured values
- typical values of distribution
< 550
< 450
V
V
Nominal impulse discharge current (wave 8/20 µs) 4)
Single impulse discharge current (wave 8/20 µs) 4)
Nominal alternating discharge current (50 Hz; 1 s) 4)
10
10
5
kA
kA
A
3)
Insulation resistance at 100 VDC
> 10
< 1.5
< 0.2
G
pF
µs
Capacitance at 1 MHz 3)
Transverse delay time 5)
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 30
< 1
~ 200
V
A
V
Weight
~ 1.4
g
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, blue positive
°C
40 ... +125
40/125/21
250 YY
250
YY
- Nominal voltage
- Year of production
Remarks on next page
PPD AB PD / PPD AB PM
Version: 03 / 2020-03-23