Switching Spark Gap
FS06X-1N
Ordering code: B88069X3690S102
Nominal breakdown voltage VN
600
V
Initial values 2)
1)
Static breakdown voltage VS
First ignition value VS, FTE after 24 hours in darkness
V
V
≤ 720
Following ignition values VS, FIV
560 ... 680
Electrical life time 3)
Breakdown voltage VB
First ignition value VB, FTE after 24 hours in darkness
V
≤ 750
Ignition time tI at V0 during life
Following ignition values VB, FIV
ms
V
≤ 90
540 ... 700
Switching operations
at -40; +25; +125°C
40 000
Ignitions
Test circuit parameters
Open circuit voltage V0
Loading resistance R
Discharge capacitance C
Inductance L
750
V
13
kΩ
nF
µH
A
470
0,1
max. 1000
Discharge peak current IP
General technical data
Insulation resistance at 100 V
Early ignition values between 500 ... 680 V
Breakdown time
> 10
≤ 2
≤ 50
200
~ 2
MΩ
%
ns
Hz
g
Maximum switching frequency
Weight
Marking, blue
600 WWY O
600
WW
Y
- Nominal voltage
- Calendar week of production
- Year of production
O
- Non radioactive
1)
At delivery AQL 0,65 level II, DIN ISO 2859
2)
Page 2, Fig. 1 and 2
3)
Page 2, Fig. 3 and 4
KB AB E / KB AB PM
Issue 07, 16.06.2004
Page 1 of 2