1-line filters
B85321A*A630, A101 … A501
∅ 55 mm, 63 … 500 A
Feedthrough filters
Feedthrough filters ∅ 55 mm
Technical data and measuring conditions
Rated voltage VR
Rated current IR
250 V AC, 50/60 Hz
350 and 600 V DC
Referred to 40 °C ambient temperature
Reduced current values at 400 Hz
Capacitance tolerance
Climatic category (IEC 60068-1)
Screw cap fixing
±20%
40/085/56 (–40 °C/+85 °C/56 days damp heat test)
Standard M32 × 1.5
Special fixing M27 × 1.5 for filters up to 300 A on request
Approvals
UL 1283, 250 V
Characteristics and ordering codes
IR
A
CR
VR
VR
Vtest Terminal Dimensions (mm) Ordering code
Approvals
µF
V AC V DC V DC
l +1 l1 –1 l2 –3
100 166 45
100 166 45
100 166 45
100 166 45
100 180 52
100 180 52
100 180 52
100 180 52
100 185 55
100 185 55
100 185 55
100 185 55
100 195 60
100 195 60
100 195 60
100 195 60
130 245 72
130 245 72
130 245 72
130 245 72
63 2 × 0.5 250 600 3000 M6
2 × 1.0 250 600 2500 M6
2 × 2.0 250 600 2500 M6
2 × 4.7 250 350 1700 M6
100 2 × 0.5 250 600 3000 M8
2 × 1.0 250 600 2500 M8
2 × 2.0 250 600 2500 M8
2 × 4.7 250 350 1700 M8
200 2 × 0.5 250 600 3000 M10
2 × 1.0 250 600 2500 M10
2 × 2.0 250 600 2500 M10
2 × 4.7 250 350 1700 M10
300 2 × 0.5 250 600 3000 M12
2 × 1.0 250 600 2500 M12
2 × 2.0 250 600 2500 M12
2 × 4.7 250 350 1700 M12
400 2 × 0.5 250 600 3000 M16
2 × 1.0 250 600 2500 M16
2 × 2.0 250 600 2500 M16
2 × 4.7 250 350 1650 M16
B85321A2105A630
B85321A2205A630
B85321A2405A630
B85321A2945A630
B85321A2105A101
B85321A2205A101
B85321A2405A101
B85321A2945A101
B85321A2105A201
B85321A2205A201
B85321A2405A201
B85321A2945A201
B85321A2105A301
B85321A2205A301
×
×
×
×
×
×
×
×
×
×
×
×
×
×
B85321A2405A301 –
B85321A2945A301
×
B85321A2105A401 –
B85321A2205A401 –
B85321A2405A401 –
B85321A2945A401 –
× = approval granted
Please read Cautions and warnings and
Important notes at the end of this document.
11 01/06