5秒后页面跳转
B84144A0200R120 PDF预览

B84144A0200R120

更新时间: 2024-03-03 10:09:22
品牌 Logo 应用领域
东电化 - TDK /
页数 文件大小 规格书
16页 779K
描述
3-phase/4-Lines(520V), Rated Current:200A

B84144A0200R120 数据手册

 浏览型号B84144A0200R120的Datasheet PDF文件第9页浏览型号B84144A0200R120的Datasheet PDF文件第10页浏览型号B84144A0200R120的Datasheet PDF文件第11页浏览型号B84144A0200R120的Datasheet PDF文件第13页浏览型号B84144A0200R120的Datasheet PDF文件第14页浏览型号B84144A0200R120的Datasheet PDF文件第15页 
4-line filters  
B84144A*R120  
for converters and power electronics  
The table below summarizes the safety instructions that must be observed without fail. A detailed  
description can be found in the relevant chapters of the databook.  
Reference chapter  
(data book),  
Topic  
Instructions  
paragraph  
Selecting a filter  
When selecting a filter, it is mandatory to observe the Selection guide for  
rated data of the equipment (such as its rated input  
current, rated voltage, harmonic content etc.) as well  
as the derating instructions in Chapters 9 and 10.  
converter filters  
Rated voltage  
When power distribution systems deviating from the  
symmetric TN-S system is to check the suitability of  
the filters and the allowed voltages including the fault  
cases.  
Power distribution  
systems,  
7
Protection from  
Active parts must be discharged within 5 s to a Safety regulations,  
residual voltages  
voltage of less than 60 V (or 50 μ C). If this limit 6.1  
Discharge resistors cannot be observed due to the operating mode, the  
hazardous point must be permanently marked in a  
clearly visible way.  
Filters which are not permanently connected (e.g.  
when the test voltage is applied to the filter at the  
incoming goods inspection) must be discharged after  
the voltage has been switched off.  
Safety regulations,  
6.2  
Installing and  
removing of filters  
When installing and removing our filters, a Safety regulations,  
voltage-free state must be set up and secured with 6.4  
observance of the five safety rules described in  
EN 50110-1.  
Installation  
Use in IT systems The special features of the IT system ("first fault case" Power distribution  
and other fault cases) shall be observed.  
system (network  
types), 7.6  
Safety notes on  
leakage currents  
The filter leakage currents specified in the data book Leakage current,  
are intended for user information only.The maximum 8.4  
leakage current of the entire electrical equipment or Leakage current,  
appliance has to be limited for safety reasons. Please 8.6  
obtain the applicable limits for your application from  
the relevant regulations, provisions and standards.  
Voltage derating  
If the permissible limits for the higher-frequency Voltage derating,  
voltages at the filter are exeeded, the filter may be 9.8  
damaged or destroyed.  
Hazards caused by  
overloading the  
filters  
Current derating at Non-observance of the current derating may lead to Current derating,  
elevated ambient  
temperatures  
overheating and consequently represents a fire 10.1  
hazard.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 12 of 16  

与B84144A0200R120相关器件

型号 品牌 获取价格 描述 数据表
B84144A0200R140 EPCOS

获取价格

THREE PHASE EMI FILTER
B84144A0200R140 TDK

获取价格

3-phase/4-Lines(520V), Rated Current:200A
B84144-A120-R EPCOS

获取价格

4-Line Filters for Converters and Power Electronics
B84144-A150-R EPCOS

获取价格

4-Line Filters for Converters and Power Electronics
B84144-A16-R EPCOS

获取价格

4-Line Filters for Converters and Power Electronics
B84144-A180-R EPCOS

获取价格

4-Line Filters for Converters and Power Electronics
B84144-A25-R EPCOS

获取价格

4-Line Filters for Converters and Power Electronics
B84144-A36-R EPCOS

获取价格

4-Line Filters for Converters and Power Electronics
B84144-A50-R EPCOS

获取价格

4-Line Filters for Converters and Power Electronics
B84144-A80-R EPCOS

获取价格

4-Line Filters for Converters and Power Electronics