SMT gate-drive transformers
InsuGate series
B78541A
Technical data and measuring conditions
Specified at +25 °C if not mentioned otherwise, all values without tolerances are typical values.
Typical operational frequency
100 ... 500 kHz
High voltage test AC (N1, core) / N2
High voltage type test AC, (N1, core) / N2
Insulation resistance RISO (N1, core) / N2
3 kVRMS, 50 Hz, 1 sec
3.75 kVRMS, 50 Hz, 60 sec
>100 M
Partial discharge inception voltage (N1, core) / N2 >1050 Vpeak (type test)
Partial discharge extinction voltage (N1, core) / N2 >840 Vpeak (type test)
Surge voltage test (N1, core) / N2, type test
Creepage distance (N1, core) / N2
Clearance distance (N1, core) / N2
Resistance to reflow soldering heat
6 kVpeak; 1.2/50 µs
9.2 mm
8.14 mm
In accordance with JEDEC J-STD-020D
Tpeak = +245 °C (Tpeak –5 °C for 30 seconds)
–40 °C ... +150 °C (component)
–25 °C ... +40 °C, humidity 75% RH
Approx. 2 g
Operating temperature range
Storage conditions
Weight
Characteristics and ordering codes
Ordering code
Turns ratio
N1:N2 or
LN1 µH
Lleak, typ
E*dtN1 1) µVs
(unipolar/
RDC,N1
@100 kHz, µH
m
N1:N2a:N2b 100 mV
1 : 1.08 50
1 : 1.07 : 0.6 50
@N2 shorted bipolar), @T<150 °C
B78541A2467A003
0.6
0.7
15 / 30
15 / 30
250
420
B78541A2492A003
ˆ
1) T 150 °C, B = 200 mT, B = 400 mT (bipolar mode). The maximum volt-sec rating limits the peak flux densitiy to
ˆ
B= 200 mT when used in a unipolar drive application. For bipolar drive applications, a maximum volt-sec of two times
is acceptable (B 400 mT).
Ordering code
RDC,N2a
RDC,N2b
CpN1/N2
pF
Schematic
m
m
@20 kHz, 1 V
B78541A2467A003
B78541A2492A003
250
350
n.a.
240
4
4
A1
A2
Schematics
Please read Cautions and warnings and
Important notes at the end of this document.
4
8/23