AZ2110/AZ2120
RELAY ORDERING DATA
STANDARD RELAYS: UL 508: 1/8” Clearance, 1/4” Creepage
COIL SPECIFICATIONS
ORDER NUMBER*
Nominal
Coil
Max.
Continuous
VDC
Coil
Resistance
10ꢀ
Must
Operate
VDC
Form A (SPST)
Form C (SPDT)
VDC
5
6
9
12
15
18
24
48
70
110
7.3
8.9
27
40
97
155
256
3.75
4.5
6.75
9.0
11.25
13.5
18.0
36.0
52.5
82.5
AZ2110–1A–5D
AZ2110–1A–6D
AZ2110–1A–9D
AZ2110–1A–12D
AZ2110–1A–15D
AZ2110–1A–18D
AZ2110–1A–24D
AZ2110–1A–48D
AZ2110–1A–70D
AZ2110–1C–5D
AZ2110–1C–6D
AZ2110–1C–9D
AZ2110–1C–12D
AZ2110–1C–15D
AZ2110–1C–18D
AZ2110–1C–24D
AZ2110–1C–48D
AZ2110–1C–70D
13.9
17.5
22.5
27.4
36.1
68.4
104.4
163.2
380
660
2,560
5,500
13,450
AZ2110–1A–110D AZ2110–1C–110D
STANDARD RELAYS: 1/16” Clearance, 1/8” Creepage
COIL SPECIFICATIONS
ORDER NUMBER*
5
7.3
27
3.75
AZ2111–1A–5D
AZ2111–1C–5D
AZ2111–1C–6D
AZ2111–1C–9D
AZ2111–1C–12D
AZ2111–1C–15D
AZ2111–1C–18D
AZ2111–1C–24D
AZ2111–1C–48D
AZ2111–1C–70D
AZ2111–1C–110D
6
8.9
40
4.5
AZ2111–1A–6D
AZ2111–1A–9D
AZ2111–1A–12D
AZ2111–1A–15D
AZ2111–1A–18D
AZ2111–1A–24D
AZ2111–1A–48D
AZ2111–1A–70D
AZ2111–1A–110D
9
13.9
17.5
22.5
27.4
36.1
68.4
104.4
163.2
97
155
256
380
6.75
9.0
12
15
18
24
48
70
110
11.25
13.5
18.0
36.0
52.5
82.5
660
2,560
5,500
13,450
For quick
* Substitute “1B” in place of the “1A” to indicate 1 Form B contact. To indicate Class F version, add suffix “F”.
connect terminals on contacts substitute “2120” or “2121” in place of “2110” or “2111”.
UL/CUR File E44211 Approved Contact Ratings
Form A
(NO)
Form B
(NC)
Form C
NO
Load Type
Cycles
Volts
NC
General Purpose
(Inductive)
Resistive
100,000
30,000
100,000
100,000
100,000
100,000
6,000
125 or 240 VAC
277 VAC
125 or 240 VAC
30 VDC
277 VAC
240 VAC
250 VAC
125, 240, 277 VAC
277 VAC
30 A
30 A
30 A
20 A
20 A
15 A
40 A
6 A
20 A
15 A
30 A
15 A
10 A
—
—
—
3 A
—
30 A
30 A
30 A
20 A
—
—
40 A
6 A
15 A
30 A
15 A
10 A
—
—
—
3 A
—
Ballast
6,000
6,000
—
Pilot Duty
6,000
125 VAC
125 VAC
125 VAC
240 VAC
277 VAC
125 VAC
240 VAC
125 VAC
800 VA
800 VA
690 VA
1152 VA
764 VA
1 HP
290 VA
—
—
768 VA
—
1/4 HP
1 HP
—
800 VA
690 VA
470 VA
1152 VA 768 VA
764 VA
1 HP
290 VA
—
275 VA
30,000
100,000
6,000
100,000
6,000
—
1/4 HP
1 HP
—
Motor Load
6,000
3 HP
1 HP
2 HP
1 HP
30,000
100,000
30,000
125 or 277 VAC
125 VAC
3/4 HP
96 LRA
30 FLA
82.8 LRA
27 FLA
80 LRA
30 FLA
60 LRA
20 FLA
15 A
5 A
—
—
TV–5
—
—
3/4 HP
60 LRA
20 FLA
82.8 LRA
27 FLA
60 LRA
20 FLA
60 LRA
20 FLA
15 A
5 A
—
—
TV–5
—
—
Definite Purpose
(LRA-Locked Rotor)
(FLA-Full Load)
33 LRA
10 FLA
—
33 LRA
10 FLA
—
100,000
30,000
125 VAC
240 VAC
277 VAC
—
—
33 LRA
10 FLA
—
—
—
—
3 A
3 A
—
33 LRA
10 FLA
—
—
3 A
3 A
—
—
TV–3
TV–3
100,000
Tungsten
6,000
6,000
6,000
6,000
25,000
25,000
125 VAC
240 VAC
120 VAC
240 VAC
120 VAC
120 VAC
TV–5
TV–3
TV–3
Note: See AZ2100 Data Sheet for more complete UL and CUR approved contact ratings.