Discontinued as of September 30, 2010
AXW
SPECIFICATIONS
1. Characteristics
Item
Specifications
Conditions
Rated current
AWG#22, 24: 3A, AWG#26: 2A, AWG#28: 1A
250V AC
Rated voltage
Electrical
characteristics
Breakdown voltage
Insulation resistance
1,000V AC for 1 min.
Min. 1,000MΩ
Detection current: 1mA
Using 500V DC megger
Measured based on the HP4338B measurement method of
JIS C 5402
Contact resistance
Max. 20mΩ
Measured by steel-pin-gauge with 0.64 0.01mm square
(surface roughness 0.1µm)
Unit removal force
Min. 0.343N {35gf}
Max. 2.94N {300gf} × No. of contacts
500 times
Mechanical
characteristics
Composite insertion force
Insertion and removal life
Life time
characteristics
Repeat insertion and removal speed of max. 600 times/hour
No freezing at low temperatures
Ambient temperature of cables should be considered
Ambient temperature
Vibration resistance
–50°C to 105°C
No interruption of current longer than 1µs
(Max. carrying current 100mA should be impressed during
the test)
Double amplitude: 1.52mm
Frequency: 10 to 55Hz (for 3 axes)
Environmental
characteristics
No interruption of current longer than 1µs
(Max. carrying current 100mA should be impressed during
the test)
Shock resistance
490m/s2 {50G} (for 3 axes)
2. Materials and surface treatment
Part name
Materials
Surface treatment
Housing
Glass fiber reinforced PBT (UL94V-0)
Glass fiber reinforced PBT (UL94V-0)
—
—
Semi-cover
Cover
Glass fiber polycarbonate resin (UL94V-0)
Vertical type hood cover (16, 20 contact)
Hood cover
—
Contact portion:
Ni plating on base, Au plating on surface
Contact pressure portion:
Contact
Copper alloy
Ni plating on base, Sn plating on surface
Lead wire bundling metal
(enclosed with vertical type hood cover)
Steel plate
—
—
Lead wire bundling band
(enclosed with angled type hood cover)
Polyimide resin
3. Applicable cable
No.
Cross section area
0.3 mm2
External figure
1.5 to 1.1 dia.
Rated current
Remarks
AWG#22
AWG#24
AWG#26
AWG#28
3A
3A
2A
1A
12 wires/0.18 should used
0.2 mm2
0.14mm2
0.08mm2
1.3 to 1.1 dia.
The CAD data of the products with a CAD Data mark can be downloaded from: http://panasonic-electric-works.net/ac
DIMENSIONS (Unit: mm)
• Housing with contacts
Dimension table (mm)
CAD Data
No. of
Polarity
A
B
contacts
guide
10
10
14
16
20
26
30
34
40
50
60
64
0
1
1
1
1
1
1
1
1
1
1
1
17.3
17.3
22.4
24.9
30.0
37.6
42.7
47.8
55.4
68.1
80.8
85.9
10.16
10.16
15.24
17.78
22.86
30.48
35.56
40.64
48.26
60.96
73.66
78.74
14.5 0.2
14.2
6.0 0.2
A
B 0.2
2.54 0.1
2.54 0.1
General tolerance: 0.3
Note) Dimensions of the housing without contact is the same as the right figure.