ATR285SFPBF PDF预览

ATR285SFPBF

更新时间: 2024-01-17 15:26:57
品牌 Logo 应用领域
英飞凌 - INFINEON 局域网输出元件
页数 文件大小 规格书
10页 71K
描述
1-OUTPUT 30W DC-DC REG PWR SUPPLY MODULE

ATR285SFPBF 技术参数

是否Rohs认证: 符合生命周期:Active
包装说明:,Reach Compliance Code:compliant
风险等级:5.74模拟集成电路 - 其他类型:DC-DC REGULATED POWER SUPPLY MODULE
最大输入电压:40 V最小输入电压:16 V
标称输入电压:28 VJESD-30 代码:R-XDFM-P10
功能数量:1输出次数:1
端子数量:10最高工作温度:85 °C
最低工作温度:-20 °C最大输出电压:5.05 V
最小输出电压:4.95 V标称输出电压:5 V
封装主体材料:UNSPECIFIED封装形状:RECTANGULAR
封装形式:FLANGE MOUNT峰值回流温度(摄氏度):260
认证状态:Not Qualified表面贴装:NO
技术:HYBRID温度等级:OTHER
端子形式:PIN/PEG端子位置:DUAL
处于峰值回流温度下的最长时间:40最大总功率输出:30 W
微调/可调输出:NOBase Number Matches:1

ATR285SFPBF 数据手册

 浏览型号ATR285SFPBF的Datasheet PDF文件第1页浏览型号ATR285SFPBF的Datasheet PDF文件第2页浏览型号ATR285SFPBF的Datasheet PDF文件第4页浏览型号ATR285SFPBF的Datasheet PDF文件第5页浏览型号ATR285SFPBF的Datasheet PDF文件第6页浏览型号ATR285SFPBF的Datasheet PDF文件第7页 
ATR28XXS Series  
ATR2805S  
Table I. Electrical performance Characteristics - continued  
Test  
Symbol  
Conditions  
Group A  
Subgroups  
Device  
Types  
Limits  
Units  
-55°C TC +125°C  
VIN = 28VDC ±5%, CL = 0  
Unless otherwise specified  
Min  
Max  
Recovery time transient step  
line changes 5, 8, 9  
TTLINE  
Input step 16V to/from  
40VDC, IOUT = 6000mA  
4,5,6  
01  
10  
ms  
Turn on overshoot  
VTonOS  
TonD  
TrLF  
IOUT =0 and 6000mA  
IOUT =0 and 6000mA  
4,5,6  
4,5,6  
4,5,6  
01  
01  
01  
500  
25  
25  
mV pk  
ms  
ms  
Turn on delay 10  
Load fault recovery 5, 10  
Notes to Specifications  
1
2
3
4
Parameter guaranteed by line and load regulation tests.  
Bandwidth guaranteed by design. Tested for 20 KHz to 2 MHz.  
Output voltage measured at load with remote sense leads connected across load.  
Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess of  
the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry, appearing  
as a short circuit during turn on.  
5
6
Parameter shall be tested as part of design characterization and after design or process changes. Thereafter parameters shall be  
guaranteed to the limits specified in table I.  
An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short circuit  
protection and is the condition of maximum power dissipation.  
7
8
Load step transition time between 2 and 10 microseconds.  
Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1 percent of VOUT at 50 percent  
load.  
9
Input step transition time between 2 and 10 microseconds.  
10 Turn on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the  
inhibit pin (pin 2) while power is applied to the input.  
www.irf.com  
3

与ATR285SFPBF相关器件

型号 品牌 描述 获取价格 数据表
ATR285SPBF INFINEON 1-OUTPUT 30W DC-DC REG PWR SUPPLY MODULE

获取价格

ATR28XXD INFINEON ADVANCED ANALOG HYBRID-HIGH RELIABILITY DC/DC CONVERTERS

获取价格

ATR28XXD_07 INFINEON HYBRID-HIGH RELIABILITY DC/DC CONVERTER

获取价格

ATR28XXS INFINEON HYBRID-HIGH RELIABILITY DC/DC CONVERTERS

获取价格

ATR28XXS_07 INFINEON HYBRID-HIGH RELIABILITY DC/DC CONVERTER

获取价格

ATR28XXT INFINEON HYBRID-HIGH RELIABILITY DC/DC CONVERTER

获取价格