DC and AC Operating Conditions
Commercial
0°C - 70°C
5V ± 5%
Industrial
-40°C - 85°C
5V ± 10%
Operating Temperature (Case)
V
CCINT or VCCIO (5V) Power Supply
CCIO (3.3V) Power Supply
V
3.0V - 3.6V
3.0V - 3.6V
DC Characteristics
Symbol Parameter
Condition
Min
Typ
Max
Units
Input or I/O Low
Leakage Current
IIL
VIN = VCC
-2
-10
µA
Input or I/O High
Leakage Current
IIH
2
10
40
Tri-State Output
IOZ
VO = VCC or GND
-40
µA
Off-State Current
Com.
Ind.
120
150
mA
mA
µA
µA
Std Mode
Power Supply Current,
Stand-by
VCC = Max
VIN = 0, VCC
ICC1
Com.
Ind.
100
100
“Z” Mode
Power Supply Current,
ICC2
VCC = Max
VIN = 0, VCC
“PD” Mode
4
10
mA
mA
Power Down Mode
Output Short Circuit
IOS
VOUT = 0.5V
-150
Current
Com.
Ind.
4.75
4.5
5.25
5.5
V
V
V
V
VCCIO
Supply Voltage
5.0V Device Output
3.3V Device Output
VCCIO
VIL
Supply Voltage
3.0
3.6
Input Low Voltage
-0.3
0.8
VCCINT
0.3
+
VIH
Input High Voltage
Output Low Voltage
Output High Voltage
2.0
V
V
Com.
Ind.
0.45
VIN = VIH or VIL
VCCIO = MIN, IOL = 12 mA
VOL
VIN = VIH or VIL
VCCIO = MIN, IOH = -4.0 mA
VOH
Note:
2.4
V
Not more than one output at a time should be shorted. Duration of short circuit test should not exceed 30 sec.
Pin Capacitance
Typ
8
Max
10
Units
pF
Conditions
CIN
VIN = 0V; f = 1.0 MHz
CI/O
8
10
pF
VOUT = 0V; f = 1.0 MHz
Note:
Typical values for nominal supply voltage. This parameter is only sampled and is not 100% tested.
The OGI pin (high-voltage pin during programming) has a maximum capacitance of 12 pf.
ATF1504ASZ