AC-DC Converter
DIP-Package
ATD-30 Series, 30Watt
ELECTRICAL
Output
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Output voltage accuracy
--
Full input voltage range
--
%
1.0
2.0
Line regulation
Load regulation
--
--
--
--
%
%
0.5
1.0
0.1
150
--
Vout-line
Vout-load
--
Vin from 100Vac to 240Vac
20%-100% load
No load power
consumption
--
--
--
--
W
Ripple
50
--
--
mV
ms
Vripple
Turn-on delay time
--
--
100
Protection
Over current
Over voltage
Short circuit
150%Io, continuous automatic recovery
Yes
Continuous automatic recovery
Environment
Storage
Humidity: 5% RH to 95% RH
-40
-40
10
--
--
--
--
+85
+75
90
Tstorage
Ta
Ambient operating
temperature
--
Operating relative
humidity
Non condensing
--
%
Ha
MTBF
300
--
kHrs
TMTBF
Dimension(LxWxH)
70.0x48.0x23.5mm
Safety
Isolation Voltage
Input-Output: 4000Vac 1.5mA//1min
Input-Output: 100M @500Vdc
Isolation resistance
Notes: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 and
Vin = 100Vac to 240Vac.
www.pairuigroup.com
Page: 2 / 4
Date: 03/21/2019
*Subject to change without notice