Electrical Specifications (DC)
For operating T = +25°C
A
Parameter
Sym.
Min.
Typ.
Max.
Units
Conditions
Fig.
Note
Output Withstand
Voltage
|VO(OFF)
|
400
450
V
VF =0.8V, IO=250 A
5
Output Leakage
Current
IO(OFF)
VR
0.005
1
A
V
VF =0.8V, VO=400V
IR =10 A
Input Reverse
Breakdown Voltage
5
Input Forward
Voltage
VF
1.1
1.3
25
8
1.6
35
10
V
IF =5mA
6, 7
8, 9
Output
On-resistance
R(ON)
IF =5mA, IO=100mA,
Pulse 30ms
6
ASSR-4119
Connection B
IF =5mA, IO=200mA,
Pulse 30ms
Switching Specifications (AC)
For operating T = +25°C
A
Parameter
Sym.
TON
Min.
Typ.
0.7
Max.
5.0
Units
Conditions
Fig.
Note
Turn On Time
Turn Off Time
ms
ms
IF =5mA, IO=100mA
IF =5mA, IO=100mA
TOFF
0.04
5.0
Notes:
1. For derating, refer to Figure 1, 2, 3 and 4.
2. The voltage across the output terminals of the relay should not exceed this rated withstand voltage. Over-voltage protection circuits should
be added in some applications to protect against over-voltage transients.
3. Threshold to switch device is I 0.5mA, however, for qualified device performance over temperature range, it is recommended to operate at
F
I =5mA.
F
4. Device is considered as a two terminal device:
ASSR-4118 - pin 1, 2 shorted and pin 3, 4 shorted.
ASSR-4119 - pin 1, 2, 3 shorted and pin 4, 5, 6 shorted.
ASSR-4128 - pin 1, 2, 3, 4 shorted and pin 5, 6, 7, 8 shorted.
5. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your
equipment level safety specification, or Avago Technologies Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
6. During the pulsed R
measurement ( I duration 30ms), ambient (T ) and case temperature (T ) are equal.
O A C
(ON)