AMIS-710208-A7: 200dpi CIS Module
Data Sheet
8.0 Recommended Operating Conditions
Table 5 lists the recommended operating conditions at 25°C
Table 5: Recommended Operating Conditions at 25°C
Parameter
Power supply
Symbol
Vdd
Vn
VLED
Idd
Min.
4.5
-5.5
4.5
Typ.
5.0
-5.0
5.0
Max.
5.5
-4.5
5.5
27
Units
V
V
V
22
25
mA
Ivn
4
5
6
mA
ILED
Vih
Vil
100
Vdd -1.0
0
150
Vdd - 0.5
200
Vdd
0.8
5.0
mA
V
V
MHz
Input voltage at digital high
Input voltage at digital low
Clock frequency
Fclk
4.0
Clock pulse high duty cycle
Clock pulse high duration
Integration time (1)
25
%
ns
ms
Clock
Tint
Tint
Fclk
Vpavg
Top
62.5 (1)
0.145(2)
Line scan rate (2)
176
4.0
1.65 +/-0.05
25
@ 4.0MHz clock frequency
µsec
Clock frequency (3)
Bright output voltage (4)
Operating temperature
Notes:
MHz
Volts
°C
50
1.
2.
The minimum tint is specified with the maximum 5.0MHz clock frequency.
Tint is the line scan rate or integration time. It is the time between two start pulses. Hence, the minimum integration time is fixed by the highest clock frequency.
Here it is specified with a 4.0MHz clock frequency.
3.
4.
Fclk is the main clock frequency, as is the pixel rate. Although the specification uses 4.0MHz, the module operates up to a maximum clock frequency of 5MHz.
Vpavg = Σ Vp(n) / 704; where Vp is the pixel amplitude in volts and where n is sequential pixel number in one line scan.
AMI Semiconductor – Jan. 06, M-20507-001
5