Series AMEC40-MAZ
40 Watt | AC-DC Converter
Isolation Specifications
Parameters
Tested I/O voltage
Input FG
Output FG
Conditions
3 sec
Typical
4000
1500
1500
>1000
Maximum
Units
VAC
VAC
VAC
MΩ
3 sec
3 sec
Isolation Resistance
General Specifications
Parameters
Switching frequency
Over current protection
Over voltage protection
Short circuit protection
Short Circuit restart
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Conditions
Typical
47
110
Maximum
Units
KHz
%
Auto recovery
140
110
Zener diode clamp
Hiccup mode, indefinite
Auto recovery
%
With derating above 50ºC
Non condensing
-40 - +85
oC
oC
100
95
-40 to +95
0.02
Free air convection
oC
% / oC
Humidity
Case material
Weight
% RH
g
Metal
270
Dimensions (L X H X W)
MTBF
4.92 x 2.56 x 1.38 inches
125 x 65 x 35mm
> 800 000 hrs (MIL-HDBK -217F, t=+25oC)
Environment Approval
Test
Parameters
Conditions
Wave form
Half sine wave
Acceleration amplitude
Bump duration
Converter operation
Number of bumps
Test mode
Displacement
Acceleration
Converter operation
5gn
30 ms
Shock
Before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine, 10-100Hz, speed 0.05Hz/s
1 mm
3g, 3 loops 30min one cycle, 3h total, every axis tested
Before and after test, body mounted (on chassis)
Vibration
Safety Specifications
Parameters
Agency approvals
cULus, CE, CB Scheme
EMI - Conducted and radiated emission
EN55011, class B
Medical Electrical Equipment
Harmonic Current Emissions
EN 60601-1, CSA-C22.2 No. 601.1-M90
IEC/EN 61000-3-2, (EN60555-2)
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
Standards
IEC 61000-4-5
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11