Click on Series name for product info on aimtec.com
Series AME5-VZ
5 Watt | AC-DC / DC-DC Converter
FEATURES:
• I/O Isolation 4000VAC
• Continuous Short circuit protection
• Regulated Output
• Operating Temp: -40 °C to +85 °C
• Input: 85-264VAC, 47-63Hz, or 100-370VDC
• Over current, Over Voltage Protection
• Compact package
• Efficiency up to 82%
Picture coming soon
Models
Single output
Maximum
Output
Voltage
(V)
Output
capacitive
Current max
Load
Efficiency
230VAC
(%)
Input Voltage
Input Voltage
(VDC)
Model
(VAC/Hz)
(A)
(µF)
AME5-3.3SVZ
AME5-5SVZ
AME5-9SVZ
AME5-12SVZ
AME5-15SVZ
AME5-24SVZ
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
100-370
100-370
100-370
100-370
100-370
100-370
3.3
5
9
12
15
24
1.25
1
0.55
0.42
0.330
0.23
8100
6800
1200
1000
680
70
75
77
79
80
82
270
Input Specifications
Parameters
Conditions
115 VAC
230 VAC
115 VAC
230 VAC
Typical
Maximum
125
Units
mA
mA
A
A
mA
A
Current (full load)
80
10
20
Inrush current <2ms (cold start)
Leakage current
External fuse
230VAC/50Hz
Recommended slow blow type
0.3
1
Output Specifications
Parameters
Voltage accuracy
Conditions
Typical
±2
Maximum
Units
%
Line regulation
Load regulation (single output)
Minimum load
Full load
0%-100% load
Single output
±0.5
±1
0
%
%
%
Ripple & Noise *
50
15
80
150
mV p-p
ms
ms
115VAC, 20MHz bandwidth
230VAC, 20MHz bandwidth
Hold-up time
Isolation Specifications
Parameters
Tested I/O voltage
Conditions
60 sec
Typical
Rated
4000
Units
VAC
MΩ
Isolation Resistance
>1000
General Specifications
Parameters
Protection class
Conditions
Typical
Class I
150-300
Maximum
Units
Over current protection
Over voltage protection
Short circuit protection
Operating temperature
Storage temperature
Temperature coefficient
Cooling
% of Iout
Zener diode clamp
Continuous, Auto recovery
See derating curve
-40 to +85
-40 to +105
oC
oC
% / oC
±0.02
Free air convection
www.aimtec.com
F 052e R8.B
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only