AHE28XXD Series
AHE2815D
Table III. Electrical Performance Characteristics - continued
Test
Symbol
Conditions
Group A
Subgroups
Device
Types
Limits
Unit
≤
≤
-55°C Tc +125°C
Vin = 28 Vdc ±5%, CL = 0
unless otherwise specified
Min
Max
70
Recovery time
step transient
TTLOAD
50% load to/from 100% load
4
All
µs
load changes 1, 7
5,6
100
No load to 50% load
50% load to no load
Input step 17 to 40V dc
4,5,6
4,5,6
4,5,6
All
All
All
1500
5.0
1500
ms
mV pk
Output response
transient step
VOTLINE
line changes 5, 12
Input step 40 to 17V dc
Input step 17 to 40V dc
4,5,6
4,5,6
All
All
-1500
4.0
Recovery time
transient
TTLINE
ms
step line
changes 1, 5, 12
Input step 40 to 17V dc
4,5,6
4,5,6
All
All
4.0
600
Turn on
VTonOS
TonD
TrLF
mV pk
ms
±
IOUT = 0 and 500mA
overshoot 9
Turn on delay 2, 9
4,5,6
4,5,6
All
All
10
10
±
IOUT = 0 and 500mA
Load fault
ms
recovery 12
Notes to Specifications
1
2
Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±0.1 % of VOUT at 50 % load.
Turn on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the
inhibit pin (pin 2) while power is applied to the input.
3
An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short circuit
protection and is the condition of maximum power dissipation.
4
5
Total power at both outputs. For operation at 16Vdc input, derate output power by 33 %.
Input step transition time between 2.0µs and 10µs.
6 Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess
of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry,
appearing as a short circuit during turn-on.
7
8
9
Load step transition time between 2.0µs and 10µs.
Bandwidth guaranteed by design. Tested for 20KHz to 2.0MHz.
Tested at each output.
10 When operating with unbalanced loads, at least 25 % of the load must be on the positive output to maintain regulation.
11 Parameter guaranteed by line and load regulation tests.
12 Parameter shall be tested as part of design characterization and after design or process changes. Thereafter parameters shall be
guaranteed to the limits specified in Table III.