AH1895
Absolute Maximum Ratings (Note 6) (@TA = +25°C, unless otherwise specified.)
Symbol
VDD
Parameter
Rating
6
Unit
V
Supply Voltage (Note 7)
Reverse Supply Voltage
Output Current (source and sink)
Magnetic Flux Density
-0.3
3.5
V
VDD_REV
IOUTPUT
B
mA
Unlimited
X1-DFN1216-4
SOT553
230
230
mW
mW
°C
Package Power Dissipation
PD
Ts
TJ
Storage Temperature Range
-65 to +150
150
Maximum Junction Temperature
°C
ESD HBM
Human Body Model (HMB) ESD capability
8
kV
Notes:
6. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;
functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be
affected by exposure to absolute maximum rating conditions for extended periods of time.
7. The absolute maximum VDD of 6V is a transient stress rating and is not meant as a functional operating condition. It is not recommended to
operate the device at the absolute maximum rated conditions for any period of time.
Recommended Operating Conditions (@TA = +25°C, unless otherwise specified.)
Symbol
VDD
Parameter
Supply Voltage
Operating Temperature Range
Conditions
Rating
Unit
V
Operating
Operating
1.6V to 3.6V
-40 to +85
°C
TA
Electrical Characteristics (@TA = +25°C, VDD = 1.85V, unless otherwise specified.)
Symbol
VOL
Parameter
Output Low Voltage (on)
Output High Voltage (off)
Output Leakage Current
Conditions
Min
—
Typ
0.1
Max
0.2
—
Unit
IOUT = 1mA
IOUT = -1mA
V
V
VOH
VDD -0.2
—
VDD -0.1
< 0.1
Ioff
VOUT = 3.6V, Output off
1
µA
During ‘awake’ period,
TA = +25°C, VDD = 3V
During ‘sleep’ period,
TA = +25°C, VDD = 3V
—
—
2.1
2.5
—
—
mA
mA
IDD(awake)
IDD(sleep)
Supply Current
—
—
—
—
—
4.3
7.2
50
8
µA
µA
µs
ms
%
TA = +25°C, VDD = 1.85V
TA = +25°C, VDD = 3.6V
(Note 8)
Average Supply Current
IDD(avg)
13
Tawake
Tperiod
D.C.
Awake Time
Period
100
100
—
(Note 8)
50
Duty Cycle
0.1
Note:
8. When power is initially turned on, the operating VDD (1.6V to 3.6V) must be applied to guaranteed the output sampling.
The output state is valid after the second operating cycle (typical 100ms).
3 of 10
www.diodes.com
July 2013
© Diodes Incorporated
AH1895
Document number: DS35742 Rev. 1 - 2