ADuM7703
Data Sheet
DIN μ μDE μ 0884-10 INSULATION °HARA°TERISTI°S
This isolator is suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
means of protective circuits.
Table 6.
Description
Symbol
°haracteristic Unit
INSTALLATION CLASSIFICATION PER DIN VDE 0110
For Rated Mains Voltage ≤300 V rms
For Rated Mains Voltage ≤4±0 V rms
I to IV
I to IV
I to IV
40/12±/21
2
For Rated Mains Voltage ≤600 V rms
CLIMATIC CLASSIFICATION
POLLUTION DEGREE (DIN VDE 0110, TABLE 1)
MAXIMUM WORKING INSULATION VOLTAGE
INPUT TO OUTPUT TEST VOLTAGE, METHOD B1
VIORM × 1.ꢀ7± = VPR, 100% Production Test, tm = 1 Second, Partial Discharge < ± pC
INPUT TO OUTPUT TEST VOLTAGE, METHOD A
After Environmental Test Subgroup 1
VIORM
1270
VPEAK
VPEAK
VPD(M)
VPR(M)
2344
VIORM × 1.6 = VPR, tm = 60 sec, Partial Discharge < ± pC
After Input and/or Safety Test Subgroup 2/Safety Test Subgroup 3
VIORM × 1.2 = VPR, tm = 60 sec, Partial Discharge < ± pC
HIGHEST ALLOWABLE OVERVOLTAGE (TRANSIENT OVERVOLTAGE, tTR = 10 sec)
SURGE ISOLATION VOLTAGE
1.2 μs Rise Time, ±0 μs, ±0% Fall Time
SAFETY LIMITING VALUES (MAXIMUM VALUE ALLOWED IN THE EVENT OF A FAILURE)1
Case Temperature
2032
VPEAK
1±24
ꢀ000
VPEAK
VPEAK
VIOTM
VIOSM
ꢀ000
1±0
VPEAK
°C
TS
Side 1 (PVDD1) and Side 2 (PVDD2) Power Dissipation
16-Lead SOIC_W
ꢀ-Lead SOIC_IC
PSO
1.43
1.19
>109
W
W
Ω
INSULATION RESISTANCE AT TS, VOLTAGE INPUT TO OUTPUT (VIO) = ±00 V
RIO
1 See Figure 3.
2.0
16-LEAD SOIC_W
8-LEAD SOIC_IC
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
0
50
100
150
200
AMBIENT TEMPERATURE (°C)
Figure 3. Thermal Derating Curve, Dependence of Safety Limiting Values with Case Temperature per DIN V VDE V 0884-10