ADuM5401/ADuM5402/ADuM5403/ADuM5404
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
protective circuits. The asterisk (*) marking on packages denotes DIN V VDE V 0884-10 approval.
Table 6.
Description
Conditions
Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method B1
I to IV
I to III
I to II
40/105/21
2
VIORM
VPR
560
1050
V peak
V peak
VIORM × 1.875 = VPR, 100% production test, tm = 1 sec,
partial discharge < 5 pC
Input-to-Output Test Voltage, Method A
After Environmental Tests Subgroup 1
After Input and/or Safety Test Subgroup 2 VIORM × 1.2 = VPR, tm = 60 sec, partial discharge < 5 pC
and Subgroup 3
VPR
VIORM × 1.6 = VPR, tm = 60 sec, partial discharge < 5 pC
896
672
V peak
V peak
Highest Allowable Overvoltage
Safety Limiting Values
Transient overvoltage, tTR = 10 sec
Maximum value allowed in the event of a failure
(see Figure 6)
VTR
4000
V peak
Case Temperature
Side 1 Current
Side 2 Current
TS
IS1
IS2
RS
150
265
335
>109
°C
mA
mA
Ω
Insulation Resistance at TS
VIO = 500 V
600
500
400
300
200
100
0
0
50
100
150
200
AMBIENT TEMPERATURE (°C)
Figure 6. Thermal Derating Curve, Dependence of Safety Limiting Values on Case Temperature, per DIN EN 60747-5-2
RECOMMENDED OPERATING CONDITIONS
Table 7.
Parameter
Symbol
Min
Max
Unit
Operating Temperature
Supply Voltages1
VDD1 @ VSEL = 0 V
VDD1 @ VSEL = 5 V
Minimum Load
TA
−40
+105
°C
VDD
VDD
IISO(MIN)
3.0
4.5
10
3.6
5.5
V
V
mA
1 All voltages are relative to their respective ground.